Dual-Zone Operation (dCH=On)
COMMON SETTINGS
MODE:
COOL or HEAT
DIFFERENTIAL:
'diF'
ZONE 1 :
Probe:
TP-1
Relay:
Relay 1
Set Point:
SP1
ZONE 2:
Probe:
TP-2
Relay:
Relay 2
Set Point:
SP2
Selecting Thermostat MODE
Press / release the PGM button to
advance to MODE selection (as
indicated by a blinking MODE light or
the word “OFF” blinking in the
SETPOINT window).
Prese the UP or DOWN button to
select the desired thermostat MODE
(either COOL or HEAT).
Notes:
Only COOL and HEAT modes are affected when 'dCH'
is set to 'On'.
Also, the following parameters are ignored by the
thermostat when 'dCH' is set to 'On': CP, HP and Hr.
Please see TC-1 User's Guide for more information
about these parameters.