- 25 -
Show OFF (“SoF”)
The value of this parameter determines whether the
thermostat displays probe temperature or the text
“OFF” in the LCD window when the thermostat is in the
OFF mode. A value of “1” causes the thermostat to
show “OFF” while in OFF mode. A value of “0” (factory
default) causes the thermostat to display probe
temperature while in OFF mode.
Programming:
1.
Press and release the SET button until the “SoF”
parameter is displayed.
2.
Press the UP or DOWN button once to display the current
parameter value. With the current value displayed, use
the UP/DOWN buttons to toggle this parameter between
the 0 (show probe temperature) and 1 (show “OFF”).
3.
Hold the SET button to exit programming mode OR press
and release the SET button again to advance to the next
programming parameter
This parameter is only accessible while the Thermostat Configuration
menu (“CC”) is set to “On”.
- 26 -
Network Service Function
+
The SERVICE function is primarily used to register the
thermostat with a TankNET
®
server during network
installation. Once registered, the thermostat can then be
monitored and controlled via the TankNET
®
Web Software.
The SERVICE function also contains an LED, which is used to
indicate the network configuration state of the thermostat.
The typical network configuration states are:
1.
Unconfigured (factory default): In this state the
Service LED will flash ON and OFF at a rate of
approximately 1.5 hertz (times per second). This
state is normal for thermostats that have not yet
been registered with a TankNET
®
server.
1.
Configured: In this state the Service LED will remain
dark. This state is normal for thermostats that have
been registered with a TankNET
®
server.
Uninstalling a Thermostat:
The SERVICE function can also be used to remove a
thermostat from a TankNET
®
network.
CAUTION:
This operation will cause the thermostat to
become inaccessible from the TankNET
®
Web Software.
To remove the thermostat from an existing TankNET
®
network, hold down both the SET and UP ARROW buttons
simultaneously for approximately 10 seconds.
For non-networked environments in which the flashing SERVICE LED
may be undesirable, a jumper is provided inside the thermostat (J5) to
disable SERVICE LED activity.
IMPORTANT:
THIS JUMPER SHOULD REMAIN IN THE ENABLED POSITION
FOR NETWORKED THERMOSTATS.