Data Entry Disable (“dEd”)
This parameter is used to disable brix and pump-over data
entry at the thermostat. Setting the value of this parameter
equal to “1” disables brix and pump-over entry. The factory
default value of this parameter is “0” (brix and pumpover
data entry enabled).
Programming:
1.
Press and release the SET button until the “dEd”
parameter is displayed.
2.
Press the UP or DOWN button once to display the current
parameter value. With the current value displayed, use
the UP/DOWN buttons to toggle this parameter between
the 0 (brix and pumpover entry enabled) and 1 (brix and
pumpover entry disabled).
3.
Hold the SET button to exit programming mode OR press
and release the SET button again to advance to the next
programming parameter
This parameter is only accessible while the Thermostat Configuration
menu (“CC”) is set to “On”.
- 24 -
Power Up Delay (“Pud”)
This parameter is used to delay thermostatic operation for a
pseudo-random period of time immediately following power
up. Setting this parameter to a value of “1” inhibits
thermostatic operation for a period of between 240 and 320
seconds at power up. Setting the “Pud” parameter to a value
of “0” (factory default) disables this delay function. A count-
down timer (in seconds) is displayed while thermostat delay
is in effect. Pressing any front panel button during the count
down will cancel the delay and cause the thermostat to
resume normal operation.
Programming:
1.
Press and release the SET button until the “Pud”
parameter is displayed.
2.
Press the UP or DOWN button once to display the current
parameter value. With the current value displayed, use
the UP/DOWN buttons to toggle this parameter between
the 0 (no power delay) and 1 (delay at power up).
3.
Hold the SET button to exit programming mode OR press
and release the SET button again to advance to the next
programming parameter
This parameter is only accessible while the Thermostat Configuration
menu (“CC”) is set to “On”.