<Function of switches>
①
ON/ZERO key
②
OFF key
③
TARE key
④
BMI key
⑤
UP key
⑥
DOWN key
⑦
kg
/lb key
○
A
NET mark
○
B
STABILIZED mark
○
C
STEP ON mark
○
D
HEIGHT mark
○
E
BMI mark
○
F
BMI MODE mark
○
G
LO BATTERY mark
OFF
TARE
kg/lb
HEIGHT
NET
HEIGHT
BMI
BMI MODE
STABILIZED
STEP ON
LO
BATTERY
ON
ZERO
BMI MODE
SET
A
B
C
D
E
F
G
100mm
(3.9in)
5mm(0.2in)
1-1)
1-2)
<Before using>
1. Power source
Please use an AC adaptor or 6
LR6 (AA Alkaline batteries).
1) In case of using batteries (not included)
Loosen the battery box fixing screw on the side of the display box and pull out the battery
box. Place the batteries in the direction as illustrated and insert the battery box back to its
original position and tighten the battery box fixing screw. When the
is displayed and
s
is turned on in the battery replacement warning mark
s
LO BATTERY, replace all 6
batteries.
Be careful when replacing the batteries not to let the batteries fall off.
2) In case of using AC adaptor (optional part)
Insert the AC adaptor jack into the DC jack on the side of the display box and plug the AC
adaptor into the AC wall outlet. (Use our genuine optional AC adaptor.)
When using the stand
When installing the display box on the wall
①
③
②
3. Name of key Operations
4. Set up
4
5
<Check again if trouble is suspected>
(1) Nothing is displayed when
switch is pressed
●
If AC adaptor is used :
Check the connection of the AC adaptor jack to the DC jack, and the connection of the AC adaptor plug to the wall outlet.
●
If batteries are used :
The batteries may be weak. Try an AC adaptor or new LR6 (AA) batteries.
(2) Measurement is not accurate
●
Check that all legs of the scale are steady.
●
Accurate measurement may be impossible if the product is used where there is excessive vibration. Try using the product in a different place.
Please pull out the stand at the back of the
display box.
When putting away the display box, please
insert the stand in the slot on the back of the
display box.
Please screw the wall-hanging screws into the
wall (leave the screws protruding from the
wall by about 5 mm (0.2in)).
Please insert the screw heads in the holes on
the back of the display box.
Please pull down the display box lightly with
your hands.
・
If the unit is not installed properly,
there is a risk that the display box will
fall down.
・
Please avoid installing the display
box in a place where the cable will
end up being trodden on or caught on
something.
・
Please do not swing the display box
around while holding the cable.
①
②
③
④
⑤
⑥
⑦
Installation of the Equipment (Remote Display Version)
Prepare Power Source
Auto Power off Interval Setting
When the Scale power off,Press
key and hold.
Press key.
Release the holding
key.
The display turns to "Auto Power Off Interval Setting Mode"
showing "20" as 20 minutes power off setting as default.
Press
(up arrow) or
(down arrow) key and set 10 for 10 minutes and/or CONT for continuous setting if required.
Press
key to complete.
BMI MODE
SET
BMI MODE
SET
ON
ZERO
BMI MODE
SET
Caution
Place the equipment on a level surface. If the equipment is not stable, for example because not all the feet
are on a level surface, there is a risk that it will topple over and it will be impossible to obtain an accurate
measurement.
For accurate measurement, place the unit on as flat a surface as possible and adjust the level with the
adjustable feet so the bubble in the level gauge is in the center of the frame. For a pole-type unit, adjust
the level gauge, then adjust the position of the two supplementary feet (small) to the level that they
lightly touch the floor so to prevent the display box from shaking.
How to move the equipment
Level Adjustment
*Adjust the level by rotating the adjustable feet.
Level Gauge
(Remote Display Version)
*Adjust the level by rotating the adjustable feet.
Level Gauge
(Column Mounted Version)
On a flat surface, holding the pole and tilting the equipment as shown
by the drawing below makes it easier to move.
Firmly hold the bottom side with both
hands when moving the equipment.
(Column Mounted Version)
(Remote Display Version)
Supplementary
foot (small)
Summary of Contents for WB-100