8
Tanis Technologies 36 Series Filtration Unit
Revised 07.20.2020
BELT REPLACEMENT INSTRUCTIONS
1.
REMOVE ACCESS PANEL
2.
LOOSEN JAM NUT ON REVERSE TENSION BOLT
3.
TURN REVERSE TENSION BOLT INWARDS TO ALLOW
TENSIONER TO MOVE
4.
MOVE/PUSH TENSIONER PULLEY AWAY FROM BELT AND
REMOVE BELT
5.
INSTALL BELT IN REVERSE ORDER, MAKE SURE BELT IS
ALIGNED PROPERLY AND ALL GROOVES ARE IN THE
CORRECT AREA
6.
ADJUST REVERSE TENSION BOLT SO THERE IS
1/16”
-
1/8”
CLEARANCE BETWEEN BOLT AND THE BODY OF THE UNIT.