Troubleshooting Chart

 

Symptom

 

Possible Cause(s)

 

Corrective Action

 

Excessive belt noise

 

1. Belt is misaligned

 

1. Remove access panel.  Follow instructions on page 8 to ad-
just belt placement.  

 For further instruction, visit our website 

(TanisTechnologies.com) for belt adjustment video.

 

2. Belt is worn out, broken, or defective.

 

1. Remove access panel. Follow instructions on page 8 to re-
place belt.  

 For further instruction, visit our website 

(TanisTechnologies.com) for belt adjustment video.

 

Air cleaner has poor perfor-
mance.

 

1. It

s possible that the air cleaner may 

have been wired backwards upon instal-
lation.  Air will blow out the exhaust 
either way, but if wired correctly it 
should blow at about 58 mph.

 

1. If the motor is wired to run the wrong direction, disconnect 
power supply, & switch the necessary wires around to reverse 
the motors rotation with the voltage you are using.

 

2.  The bag filter may not be seated 
properly

 

2. Reach in each pocket to make sure fabric is not between 
filter stop and filter frame.

 

Air is not staying as clear as 
usual

 

1. Prefilters may be loaded with debris

 

1. Turn unit off, lock out power to unit, then replace the prefil-
ter by pushing clips out of the way and then sliding it out and 
sliding a new one in.

 

2. Bag filter(s) may be spent

 

2. Follow step (1) to remove the prefilter, then if unit is 
equipped with clips, push them out and away from the bag 
filter, slide out the old bag filter and slide in new one until clips 
snap around it.

 

Operation

 

Once installed using the above instructions, your AF

-

36xx air cleaner(s) can be operated with the flip of a 

switch. Because the AF

-

36xx series is designed as an 

Air quality Maintenance

” 

system, it is important that 

the units are turned on in the beginning of the shift and left on until the end of the shift. The reason the 
units need to remain on is because Air Cleaners train the air current throughout the entire area in order to 
ensure that all of the air is cycling through the filters. The process of training the air can take a while, but is 
usually about 30 minutes.

 

 

Maintenance

 

Follow these precautions when performing maintenance on the motor or blower. 

 

Turn off motor, and LOCK OUT electrical service to the unit.

 

LOCK OUT even when changing filters.

 

Change filters regularly to maintain optimum performance. If the performance of your air cleaners appears 
to be declining, try replacing the filters.

 

Be sure that replacement filters are always rated for the correct CFM and air flow.

 

 

NOTE FOR INSTALLING BAG FILTERS: 

 

When installing fiberglass bag filters, MAKE SURE THAT NO FABRIC IS PINCHED BETWEEN THE HEADER 
AND FILTER FRAME.  

Performance will decrease dramatically if bag filters are not properly installed.  To 

ensure no fabric is pinched, place your fingers inside each cell, and gently move each bag cell side to side, 
freeing any fabric sandwiched between the header and filter frame.

  

 

 

If the system requires maintenance exceeding filter change, read below

 

Take the unit down and place it on a level surface that allows access to the access panel of the Main 
Housing. 

To access the motor, pulleys and belt:

 Remove the access panel by removing (16) ¼

-

20x1

-

1/4

” 

bolts with a 3/8 socket.

 

Summary of Contents for MODULE-AIR AF-36 Series

Page 1: ...AF 3623 AF 3653 Description This 14 000 CFM Air Cleaner was designed for use as ambient air filtration where airborne particles are prevalent The air cleaner consists of 6 intakes and one exhaust one...

Page 2: ...ap around it Operation Once installed using the above instructions your AF 36xx air cleaner s can be operated with the flip of a switch Because the AF 36xx series is designed as an Air quality Mainten...

Page 3: ...leaners are intended to be installed at least 8 2 feet 2 5 meters above the floor 3 Specific duct design and dust collector configurations are required under standards set forth by the National Fire P...

Page 4: ...and recommendations are included for installation of your air filtration system the manufacturer does not assume responsibility for the installation of this equipment nor shall be held liable for dir...

Page 5: ...5 Tanis Technologies 36 Series Filtration Unit Revised 07 20 2020 Simple Installation Guide For a more detailed description see page 4...

Page 6: ...6 Tanis Technologies 36 Series Filtration Unit Revised 07 20 2020...

Page 7: ...7 Tanis Technologies 36 Series Filtration Unit Revised 07 20 2020...

Page 8: ...E TENSION BOLT 3 TURN REVERSE TENSION BOLT INWARDS TO ALLOW TENSIONER TO MOVE 4 MOVE PUSH TENSIONER PULLEY AWAY FROM BELT AND REMOVE BELT 5 INSTALL BELT IN REVERSE ORDER MAKE SURE BELT IS ALIGNED PROP...

Page 9: ...mined to be defective in material or workmanship can be shipped prepaid to TANIS TECHNOLOGIES or authorized service facility in which case a determination will be made whether to repair or replace the...

Reviews: