3.  Attach the pilot supply tube from the lower burner pilot  to the 

front bulk head fitting and tighten. (Fig. # 3) Ensure there are no 
leaks. 

4.  Transfer  insulation  sleeves  from  front  electrical  bulkhead 

connections  to  the  pilot  wires  leading  from  the  lower  burner 
pilot. Attach spark electrode (RED) and sensor leads from lower 
burner pilot to the front electrical bulk head. ( Fig. # 3) (The spark 
electrode connection has a red dot above it) Slide the insulation 
sleeve back onto the bulkhead connections. (Fig #4) Replace 
the ceramic fibre filler piece into the lower burner assembly.

 

A panel set must now be installed. See Installation and   

 

Operating Instructions manual for details.

 

5.  Position the grate and attach it to the floor with two screws located 

behind the front legs. (Fig. # 5)

6.  Attach the manifold supply tube from the upper  burner to the 

rear bulk head fitting and tighten. (Fig. # 6) Ensure that there are 
no leaks.

RED END

Fig. #3

Fig. #4

Fig. #5

Fig. #6

3

Summary of Contents for TC54.NG02.C

Page 1: ...tions supplied with the fireplace and should be kept together Refer to the Installation and Operating Instructions for proper gas supply safety requirements and operating instructions TC54 COUNTRY HOM...

Page 2: ...aside Place the keyhole slots in the burner over the two screws located in the firebox base Fig 1 1a b 1b Slide the burner back to engage the screws in the small part of the keyhole slot and tighten...

Page 3: ...o the front electrical bulk head Fig 3 The spark electrode connection has a red dot above it Slide the insulation sleeve back onto the bulkhead connections Fig 4 Replace the ceramic fibre filler piece...

Page 4: ...res coming from the upper burner pilot Attach spark electrode RED and sensor leads from upper burner pilot to the rear electrical bulk head Fig 9 The spark electrode connection has a red dot above it...

Page 5: ...ervice agency is responsible for the proper installation of this kit The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufactu...

Page 6: ...previ ously removed 7 Remove the screw securing the upper burner to the grate assembly Fig 15 8 Usinga1 2 wrench undothenaturalgasburnerorifice marked 28 Fig 16 9 Apply a small amount of pipe joint co...

Page 7: ...ached to the lower burner assembly Fig 17 13 Slide the pilot adjustment band over and ensure that the hole in the orifice band is showing Fig 18 indicates NG position Fig 19 indicates LP position 14 R...

Page 8: ...the conversion label Peel off the protective backing and apply the conversion label directly over the gas specifications on the rating label 22 Attach the access panel to the side of the firebox with...

Page 9: ...l Gas Propane Minimum 5 0 wc 12 5 wc Maximum 13 9 wc 13 9 wc Manifold Pressure Maximum 3 4 wc 11 0 wc Minimum 1 8 wc 5 5 wc Note To test the gas pressure turn off the gas supply before removing the pl...

Page 10: ...s leave it loose for best performance Fill the lower burner pan level with the top of the pan at rear and gradually slope forward to the firebox floor covering both lower burner tubes Place remaining...

Page 11: ...icated by the following pictures The three main logs have holes and or pins Engage each pin in the corresponding holes The four smaller logs do not have holes or pins They rest in position Locate as p...

Page 12: ...3 010410 16 TC54 NG02 C 3 2 1 4 5 7 6 Fig 33 Fig 34 Fig 35 5 6 12...

Page 13: ...d stringy The shutter may also be opened to enhance the Ember Material glow and lessen the flame height Caution Burner area may be hot Turn off the fireplace and allow the unit to cool before proceedi...

Page 14: ...4 LINE DORMONT 5019 225 9 FITTING ORIFICE INLET 5019 21 10 UPPER BURNER BRACKET 8187 5 11 1 2 14NPT BRASS LOCKNUT 5021 01 12 FLEX 1 2 LINE DORMONT 5019 223 13 BURNER TC54 REAR 5011 8302 LOG SET COMPL...

Page 15: ...010410 16 TC54 NG02 C 15 Notes...

Page 16: ...TECHNICAL SUPPORT 1 250 748 1184 www townandcountryfireplaces net 2975 Allenby Rd Duncan BC V9L 6V8 Printed in Canada...

Reviews: