background image

If the unit is to be used on propane 
convert as follows using the 
components  supplied  with  this 
burner:

CAUTION

The gas supply and electrical power 
shall  be  shut  off  before  proceeding 
with the conversion.

Note: Factory supplied components must be 
used to ensure correct input.  
After  conversion  confirm  proper  manifold 
pressure.

1.  Ensure the burner, pilot and gas 
 

supply are turned off, and the 

 

appliance has cooled.

2.  Remove the two screws securing the  
 

the burner grate. 

 

(Fig. #19)

3.   Remove  the  two  screws  securing  the 

manifold assembly to the burner. 

 

(Fig. #20)

4.   Remove the manifold assembly from the 

burner. (Fig. #21)

5.    With a ½” wrench remove the natural gas 

orifice (#32) and replace with propane 
orifice (#48)(our part # 5021.3407) 

 

(Fig. #22) 

WARNING

This conversion kit 
shall be installed by a 
qualified service agency 
in accordance with the 
manufacturer's instructions 
and all applicable codes 
and requirements of 
the authority having 
jurisdiction. 

If the information in these 
instructions is not followed 
exactly, a fire, explosion 
or production of carbon 
monoxide may result 
causing property damage, 
personal injury or loss of 
life. 

The qualified service 
agency is responsible for 
the proper installation of 
this kit. 

The installation is not 
proper and complete 
until the operation of the 
converted appliance is 
checked as specified in the 
manufacturer's instructions 
supplied with the kit.

Fig #19

Fig #20

Fig #21

Fig #22

8

TC30.NG01.C 140708

Propane Conversion

Summary of Contents for TC30

Page 1: ...s are supplementary to the Installation and Operating Instructions supplied with the fireplace and should be kept together Refer to the Installation and Operating Instructions for proper gas supply sa...

Page 2: ...2 TC30 ng01 C 140708 Notes...

Page 3: ...lk head fitting and tighten Fig 2 Ensure that there are no leaks NOTE Primary air shutter must be fully closed for Natural gas or fully open for Propane BURNER ASSEMBLY EMBER MATERIAL 7 PCS LOG SET HA...

Page 4: ...3 Attach the pilot supply tube to the bulk head fitting and tighten Fig 3 Ensure there are no leaks 4 Connect spark electrode wire ORANGE to the rear electrical bulk head fitting Connect the flame sen...

Page 5: ...ers until level with the top of the pan at rear and gradually slope forward to the firebox floor at the front covering both burner tubes 3 Place remaining ember material outside of the burner pan as d...

Page 6: ...inspect log set There should be a total of 7 logs Gas plumbing and vent con nections should be completed before proceeding Position the logs as indicated by the following pictures The three main logs...

Page 7: ...PIN HOLE TOP LEFT LOG 3 BOTTOM RHS CHUNK 4 BOTTOM CENTER CHUNK 5 BOTTOM LHS CHUNK 6 CENTER CHUNK 7 Fig 13 Fig 15 Fig 14 Fig 16 Fig 17 Fig 18 7 TC30 ng01 C 140708...

Page 8: ...enchremovethenaturalgas orifice 32 and replace with propane orifice 48 our part 5021 3407 Fig 22 WARNING This conversion kit shall be installed by a qualified service agency in accordance with the man...

Page 9: ...fold and air deflector 8 Witha7 16 wrenchloosenthepilothead on the pilot assembly by a half turn Fig 25 9 Slide the pilot adjustment band over and ensure that the hole in the orifice band is showing F...

Page 10: ...should stay down Fig 31 Replace the rubber cap 15 Fill in the date and the name of the personwhoperformedtheconversionin the white area on the conversion label Peelofftheprotectivebackingandapply the...

Page 11: ...be required to ensure a gas tight connection Correct gas pressure requirement Supply Pressure Natural Gas Propane Min Pressure 5 0 WC 12 5 WC For purpose of input adjustment Max Pressure 13 9 WC 13 9...

Page 12: ...w 5 Rotate the shutter to increase or decrease the amount of primary air 6 Reassemble in reverse order The air shutter on the burner tube controls the primary combustion air to the gas burner and is p...

Page 13: ...TUBE CONNECTION 1h PILOT BRACKET 1i HEAT SHIELD 1j HEAT SHIELD INSULATION 2a BASE LOG 2b TOP LEFT LOG 2c TOP RIGHT LOG 2d CENTER CHUNK 2e BOTTOM LHS CHUNK KIT CONTENTS 2f BOTTOM CENTER CHUNK 2g BOTTOM...

Page 14: ...14 TC30 ng01 C 140708 Notes...

Page 15: ...15 TC30 ng01 C 140708 Notes...

Page 16: ...Printed in Canada Technical support 1 877 715 2664 Web site www townandcountryfireplaces net 2975 Allenby Rd Duncan BC V9L 6V8...

Reviews: