![background image](http://html1.mh-extra.com/html/tandberg/educator-mxp/educator-mxp_user-manual_3623923046.webp)
TANDBERG Educator MXP & Professional MXP Videoconferencing System
46
configure it to the system, you will have to repeat much of the following procedure for
verification, as well as make sure that you identify the specific camera you have
connected.
2. Navigate from the main conference page to the AUDIO/VIDEO SOURCES page:
Utilities > System Setup > AUDIO/VIDEO SOURCES
3. Select CAMERA #2 under
‘
Source.
’
When you select a source, the
‘
Source
Configuration
’
and
‘
Custom Settings
’
areas will appear with the appropriate options.
4. In the
‘
Source Configuration
’
area, press
‘
Activate
’
to enable
‘
Camera #2.
’
The
button will change to ACTIVE.
5. In the
‘
Source Configuration
’
area, you can press
‘
Change Icon
’
to select a different
icon that will be associated with
‘
Camera #2.
’
The selected icon is what will be
displayed on your touch panel.
6. In the
‘
Source Configuration
’
area, press the
‘
Rename Source
’
button if you wish to
associate a specific name to
‘
Camera #2.
’
A keyboard will appear for you to type in
the desired name. Press DONE on the keyboard to accept the given name.
7. In the
‘
Custom Settings
’
area, you will see the
‘
Change Model Type
’
button. Press
this button repeatedly to toggle though the set of identifiable devices until you see
your specific device -- SONY EVI-D100.
If you did not connect the second camera before configuration, you will not see the
specific device in
‘
Change Model Type.
’
You must return to the AUDIO/VIDEO
SOURCES page, select
‘
Camera #2
’
, and select the specific camera in
‘
Change
Model Type.
’
8. Press COMPLETE when you are finished with configuration, or repeat the procedure
if you wish configure another device.
4.4.1.2 Display Equipment
Monitors
select single or dual monitor setup
Picture
“
in or Out
”
of
Picture
select PIP or POP as default video window layout options
On Screen
Messaging (OSM)
select to activate OSM for your display(s). If you intend to use the remote (handheld or emulator) OSM must
be active.
Primary Display
Mode
select Hi-Res/DVI or Video displays
Monitor Format
select Wide (16:9) or Normal (4:3) / select display resolution XGA(1024x768, SVGA (800x600), or Auto.
Room Display Type
Select
Set the type of display associated with the First and Second display connections -- Net TV, Plasma, etc. As
noted on the touch panel, the display references the physical connection on the rear interface panel.
4.4.1.3 Room Setup
Pressure Mats
This page allows the user to setup the Pressure Mat operation and presets associated with a particular mat.