Getting Started
TANDBERG Director Videoconferencing System
34
General Codec Configuration
The control system communicates with the codec through Data 1 at 9600 baud, No parity bit, 8
data bits, and 1 stop bit. The codec should be left in its default configuration with the following
exceptions. Using the IR control, the following settings should be addressed:
•
Enabled but unused ISDN lines (lines not active) should be disabled.
•
Select the
QUICK
KEY
‘System Info’
(IR control) to view line status.
•
To disable unused ISDN lines, press
MENU
on the remote control.
•
Select the menu ‘Terminal Settings’ > ‘Network’ >
‘ISDN-BRI settings’
.
•
Select the relevant ‘Line Setup’ menu and set
‘Enabled: Off’
.
•
Enter
System Name
to identify the system during an MCU conference.
•
Select ‘Utilities’ >
‘System Name’
•
Enter the name using the
NUMBER
KEYS
(as on a mobile phone).
•
Select the language you want to use in ‘Terminal Settings’ >
‘Language’
.
•
If you are using two monitors, set ‘Utilities’ >
‘Dual Monitor: On’
.
•
To activate
AES Encryption, MultiSite
TF
and/or
Presenter
, enter an option key (see
paperwork accompanying your system). See ‘Terminal Settings’ >
‘Software Options’
.
•
Press
CONNECT
on the IR control. A dial tone should be heard if the network is active.
•
Using the monitor remote control, adjust the
VOLUME
on the monitor to a level of your choice.
This volume will be the default volume for all calls.
It is critical that the following settings are configured:
•
All network and LAN information (SPIDS, IP Addresses, etc. )
•
DuoVideo Mode “Manual”
N O T E
T
HESE
SETTINGS
ARE
ESSENTIAL
FOR
OPTIMAL
SYSTEM
SETUP
.
TF
- TANDBERG F
IRST