Cleaning the Tape Mechanism
SDLT 600 Product Manual
5-6
March 2004
81-81184-02 REV A01
N
OTE
: If the tape drive is mounted in a tape automation library, the CUP/FUP
data cartridge rewinds to BOT and unbuckles in preparation for
unloading, but does not automatically eject.
5.3.4 Firmware (Code) Update Troubleshooting
Try these remedial actions if the tape drive’s code update fails:
•
Updating the same revision
If you request a code update that is the same as the code revision already on the tape drive, the
system updates the controller code but not the servo-specific code. The steps for this type of
update are the same as for a normal update.
•
Updating fails, which causes the tape drive to be reset; the problem can result from any of the
following circumstances:
Data cartridge contains incompatible update image.
Data cartridge does not contain an update image.
No data cartridge in the tape drive.
5.4
Cleaning the Tape Mechanism
This section discusses the SDLT 600 tape drive cleaning tape, maintenance considerations, and
important compatibility issues you need to be aware of.
N
OTE
: When your backup software indicates needed cleaning, or the yellow
LED on the tape drive comes on, use the SDLT CleaningTape to clean the
unit. Do not clean the tape drive unless the tape drive specifically
indicates cleaning is necessary.
Summary of Contents for SDLT 600
Page 1: ...SDLT 600 Product Manual...
Page 6: ...SDLT 600 Product Manual vi...
Page 48: ...Recording Media Specifications SDLT 600 Product Manual 3 20 March 2004 81 81184 02 REV A01...
Page 74: ...Confirming the Installation SDLT 600 Product Manual 4 26 March 2004 81 81184 02 REV A01...
Page 112: ...Unloading a Data Cartridge SDLT 600 Product Manual B 10 March 2004 81 81184 02 REV A01...
Page 124: ...X SDLT 600 Product Manual G 12 March 2004 81 81184 02 REV A01...
Page 125: ......