tams
elektronik
FD-R Basic 2
English
Setting the operating mode
This setting takes the following effects:
choice of the memory area the ongoing programming is taken over
for;
choice of the memory area the CV values are transmitted from after
a RailCom CV read-out command.
Name of CVs /
MM-registers
No.
Input value
(Default)
Remarks and Tips
Operating
mode
888
0 ... 1 (0)
Function decoder
0
RailCom transmitter
1
Please note: If the FD-R Basic 2 gets the same address as another
decoder in the same vehicle, the mentioned decoder will be
programmed anew as well. If you want to avoid this, you can interrupt
the decoder´s connection to a rail collector before programming the
FD-R Basic 2.
Setting the address
Name of CVs /
MM-registers
No.
Input value
(Default)
Remarks and Tips
Basic address 1
1 ... 255
(3)
Range of values in
DCC-Format: 1 ... 127
Tip: If a value higher than 127 is set for the basic address and the use of extended addresses
in CV #29 is set to off, the decoder does not react to signals in DCC format!
Extended
address
17
192 ... 255
(192)
Only for DCC format. Most
central units permit entering
extended addresses directly.
The CVs # 17, 18 and 29 are
set automatically to the proper
values.
18
0 ... 255
(255)
Consist
address
19
1 ... 127 (0)
= 2nd adress
In DCC format only!
Page 27