English
HELIOS
6.6. Reset
In order to restore the factory (default) settings, insert jumpers into
fields 5 and 6. Then, switch on the voltage supply while holding the
push-button pressed cor approx. 1 second. HELIOS shows taking over
the reset by the LEDs 2 to 4 flashing slowly.
Afterwards, switch off the voltage supply again.
6.7. Choosing the starting mode
You start the shuttle service either immediately after switching on the
voltage supply or only after pressing the push-button. Adjusting is
made by inserting a jumper to field 6.
Starting the shuttle service
when switching on the
voltage supply
--- inserted
Starting the shuttle service
by pressing the push-button
6 inserted
Page 52
Summary of Contents for HELIOS
Page 59: ...HELIOS English Page 59...