Z-Block Manual version 1.3
Page 16
Tamas Hydronic Systems
Z-Block Distribution Manifold Assembly
The Z-block modules with bayonet connection are manually assembled to
produce distribution manifolds with the necessary number of connections. The
operation is extremely simple, but it’s important to check that the machined
end parts are clean and free of impurities, and to lightly lubricate the O-ring
with silicone grease if necessary.
The bayonet connection system does not require the use of tools, and as such,
there is no need to place twisting or crushing force on the modules; this could
deform or damage these parts, thereby affecting their operation.
Apply a pea-sized amount of Silicon
Grease to O-Rings on Connection
Fitting. A line film of lubrication
can avoid rolling the O-ring.
1
Push locking tabs down or up to
seal the connection.
4
2
Insert Connection Fittings
and push until it stops.
3
Align Z-Blocks, and push
second block onto connection
Fittings until they stop.
Assembly