1.  Remove all packaging from the cushion and power unit. 
2.  Place the cushion on the chair, ensuring that the cushion is placed the correct way 

up with the BACK labelling facing the back of the chair. Secure cushion to chair using 

adjustable straps if applicable.

3.  Suspend power unit from chair in a convenient position 

using the carry case provided, or place on a flat surface 

in the correct orientation.

4.  Attach cushion air supply hose to power unit by matching 

up the alignment notch and groove on the ATTIVO™ 

power unit connection port and cushion hose connector 

and pushing together (Fig. 1). Ensure that this has been 

correctly clicked into place, otherwise a leak may occur.

5.  If using mains power, insert the mains adapter DC 

outlet cable plug into the side of the power unit, and the other end into a mains outlet 

and switch the outlet on. The mains adapter indicator should be illuminated. If using an 

the optional vehicle adapter, insert the DC outlet cable plug into the side of the power 

unit, and the vehicle plug into a vehicle 12V power outlet. The vehicle adapter indicator 

should be illuminated.

 

NB. The battery will charge when the unit is connected to a mains or vehicle adapter 

(indicated by battery charge status icon on display screen scrolling from left to right) and 

provides automatic continued operation if the external power supply or adapter fails. It is 

recommended to use a mains adapter when convenient to do so as this will ensure the 

battery is fully charged when needed. A fully discharged 

battery will take a number of hours to fully charge.

6.  Standby mode is automatically invoked when the power is 

switched on. Press the RUN/STOP button to initialise and 

run the seating system. When the power unit has finished 

initialising the pump screen will display ATTIVO together 

with the battery status and the comfort setting (Fig. 2)

7.  The default comfort setting is MEDIUM. The comfort 

setting can be adjusted using the up and down arrow 

buttons (see COMFORT CONTROL on page 5).

8.  The power unit will automatically lock 1 minute after last button operation when running 

to prevent inadvertent operation of button functions (except MUTE), as indicated by 

‘   ’ on the display screen. Press and hold the UNLOCK button until power unit beeps if 

further button operation is needed.

 NB. 

The display screen is only illuminated for a short period after button operation in 

battery mode.

9.  To stop the power unit, press and hold the UNLOCK button until power unit beeps and

 

‘   ‘ clears from display screen. Then press and hold the RUN/STOP button until power 

unit beeps three times to return to stand-by mode (if using the power adapter, disconnect 

it from the power unit and unplug from the power source). The power unit will then power 

off automatically after one minute of inactivity or may be forced off by pressing the MUTE 

key.

10.  Place the user manual in a safe place for future use.
It should be noted that the use of an alternating air pressure cushion will increase the patient’s 

seated height by approximately 5cm, and care should be taken to ensure the patient’s comfort 

and security regarding height of foot and arm rests.

4

Fig. 1            

Fig. 2            

Summary of Contents for ATTIVO

Page 1: ...ATTIVO Dynamic Seating System User Guidelines reducing avoidable harms ...

Page 2: ...This is a statement that alerts the user to the possibility of serious injury or other adverse reactions with the use or misuse of the device This is a statement that alerts the user to the possibility of a problem with the system associated with its use or misuse IP Ingress Protection Pump only 2 Protection against fingers or other object not greater than 80mm in length and 12mm in diameter 2 Pro...

Page 3: ...Power unit carry case l TS209 B A S E SEQUENTIAL cushion or B A S E Recliner Mat The following accessories spares are also available l 12V Vehicle adaptor charger l Spare mains lead with integral power supply 15V Mains adapter FW7362M 15 Cautions and Warnings CONTRAINDICATIONS FOR USE Alternating pressure therapy should not be used for patients with unstable fractures gross oedema burns or an into...

Page 4: ...ct fuse used l The cushion power unit and power adapter should be cleaned between patient use please refer to Care and Maintenance section for all warnings and cautions l The power unit battery is installed inside the unit and is not accessible by users Battery replacement should only be carried out by qualified Talley service personnel l The power unit must only be used with the approved power ad...

Page 5: ...e the battery is fully charged when needed A fully discharged battery will take a number of hours to fully charge 6 Standby mode is automatically invoked when the power is switched on Press the RUN STOP button to initialise and run the seating system When the power unit has finished initialising the pump screen will display ATTIVO together with the battery status and the comfort setting Fig 2 7 Th...

Page 6: ...isplay screen The MUTE button can also be used to force power off in stand by mode DATA The information menu can be activated by pressing the DATA button for 5 or more seconds while pressing the RUN STOP button then releasing the RUN STOP button while continuing to press the DATA button for a few seconds Press the DATA button when ready to exit the information menu NB Used for accessing informatio...

Page 7: ...acement should only be carried out by qualified service personnel Contact Talley or authorised dealer for battery replacement service Care and Maintenance COVER Always keep the cushion cover as clean as is practicable The material is waterproof and vapour permeable l Inspect top cover for signs of damage or wear which could result in the contamination of the interior e g tears holes damage to seam...

Page 8: ...adapter in accordance with the local regulations including WEEE requirements The power unit power adapter should be cleaned between patient use as a minimum In line with the MHRA Medical Device Alert MDA 2013 019 Talley advises customers to use pH neutral high level disinfectant cleaning products to sanitise reusable medical devices to prevent damage to materials and the degradation of plastic sur...

Page 9: ...ntee The intended design life is 5 years if fully serviced Fault Finding All sounders can be silenced and messages cleared by pressing the MUTE button once Should any fault occur press the MUTE button to reset the power unit If fault remains re occurs contact Talley WARNING INDICATORS NO BATTERY indicates battery is not correctly fitted The power unit will only operate using the power adapter whil...

Page 10: ...mensions 430mm x 430mm x 70mm 1080mm x 430mm x 70mm Weight 1 9 kg 3 9 kg The above mains adapter is considered part of the ME equipment 12V vehicle power adapter is available as an optional accessory 99 01 14 05 The ATTIVO power unit must only be used with the specific external power adapters as supplied by Talley EMI fault indicates that the unit detects the pressure sensor amplifier is adversely...

Page 11: ...nterfering equipment repaired or replaced l Reorient or relocate the interfering equipment l Increase the separation between the equipment and the possible source of the interference l Connect the equipment to an outlet on a circuit different from that to which the interfering equipment was connected Information regarding Electro Magnetic Compatibility EMC according to IEC60601 1 2 With the increa...

Page 12: ...urer and d is the recommended separation distance in meters m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol Note1 At 80 MHz and 800 MHz the higher frequency range applies Note2 These guidelines may not...

Reviews: