ENGLISH
4
7. ELECTRICAL CONNECTION
Ensure that the mains voltage is the same as the value shown on the motor plate and that there is the
possibility of making a good earth connection.
Follow the indications on the technical data plate and in this
manual, table 2.
The length of the power cable on the pump limits the installation distance, if an extension is required,
make sure that it is of the same type (e.g. SJTOW 16AWG o SJTW 15AWG depending on the installation)
see tab 2.
8. START-UP
Do not start the pump without having completely filled it with liquid, about 4 litres (1.06 gall).
If the water supply is finished, take the plug out of the socket immediately and switch off the pump. Avoid dry running.
1.
Before starting, check that the pump is properly primed, filling it completely, with clean water, through the filling
hole, after having removed the filling cap of the transparent filter (1), with your hands or with the appropriate tool
provided. This ensures that the mechanical seal is well lubricated and that the pump immediately starts to work
regularly.
Dry operation causes irreparable damage to the mechanical seal.
2.
The filling cap must be screwed on accurately until it stops (1).
3.
Insert the plug of the power cable in a 115-120V power socket.
Attention!
The pump motor will start immediately,
the water will start to come out after a maximum time of 3 minutes, depending on the depth of the water level, in
the cistern.
4.
The pump is automatically deactivated when the maximum pressure is reached. If, when using water, the pressure
falls below the minimum value, the pump is activated automatically. See Tab.2.
5.
To switch off the pump completely, take the plug out of the power socket.
In case of problems with the priming, repeat the handling until all air in the suction is disappeared.
9. ELECTRONIC CONTROL INTERFACE
9.1 Overview of the features
Description Parameters
Controller board voltage, frequency
1x115-120V, 60Hz
Power on/off indicator
Motor on/off indicator
Alarms indicator
Pressure indicator
Mode indicator
Auto Mode
Manual Mode
Dry-running protection
Anti-leakage
Max pump on protection
(30 minutes)
(A)
(B)
(C)
Summary of Contents for D-BOOSTi Series