ENGLISH 

 

Press “

MODE

” to scroll through the various operating modes (AUTO_MODE or MANUAL_MODE) or parameters to be 

modified (CUT IN and CUT OUT) or to enable certain functions (ANTI-LEAKAGE and MAX PUMP ON). While scrolling 
through the modes, the LED of the function selected will flash. On returning to AUTO_MODE the active functions will be 
highlighted by the relative LED lighting up with a steady light. See paragraph 2 (Description of the functions). 

 
Indicators on “MODE” 
AUTO MODE

: the pump will

 

work in automatic mode see 9.2.1 

MANUAL MODE

: the pump works in manual mode see 9.2.1, and the user can decide when to switch it on or off by acting 

on the “

SET

” button. SET-ON switched On SET-OFF switched Off. 

CUT-IN

: pressure setting (always enabled) minimum pressure below which the pump is activated, can be set between 22 

and 44 psi, factory setting 26 psi; the pump is activated even if the flow is less than a minimum value of 0.4 gpm, factory-
setting. 

CUT-OUT

: pressure setting (enabled) pressure above which the pump stops, the factory setting for “CUT-IN” + 1 Led, but 

can be increased to 51 psi. 
To enable it select the function by pressing “MODE” until the LED corresponding to CUT-OUT flashes then press SET to 
select the required value, exit the setting by pressing “MODE”. To disable the function, press “SET” until the light switches 
on to indicate OFF. 

ANTI-LEAKAGE: 

protection against leakage. The function can be enabled or disabled: the factory setting is disabled. 

When enabled, if the condition is such that the pump is started up more than 6 times in 2 minutes, it will be stopped and 
the error will be indicated by means of the red LED flashing slowly on “

ALARM

”. 

To enable it select the function by pressing “MODE” until the LED flashes then press SET until the “ON” LED is switched 
on. To disable it press SET until the LED switches on to indicate OFF. 
Once the cause is removed, reset the alarm, if still present, see 9.2.3. 

MAX PUMP ON: 

maximum period of operation.

 

The function can be enabled or disabled. The factory setting is disabled. 

When enabled, if the condition is such that the pump operates for more than 30 minutes, it will be stopped, no error 
indication is displayed.  
This function is used to protect the installation if a valve is left accidentally open, in the event of breakage of a pipe, or in 
applications for irrigation.

 

To enable it, select the function by pressing “MODE” until the LED corresponding to the MAX PUMP ON function is switched 
on, then press SET until the “ON” LED comes on. To disable it, press SET until the LED switches on to indicate OFF. 

 

(C) SET selection button 

Selectable modes: 

1) Reset Alarms; 
2) Enable/disable in MODE (MAX_PUMP_ON, ANTILEACKAGE) 
3) Increases parameters in MODE (CUT_IN; CUT_OUT); 
4) Motor ON/OFF in MANUAL MODE; 
5) Pump active/pump in standby in AUTO MODE 

 

Press “

SET

” to modify the parameters; if the LED is switched to MODE-CUT IN or MODE-CUT OUT, the value will be 

shown on the pressure indication LED bar. On pressing “

SET

” the value will increase. After setting the required value, exit 

the modification by pressing “

MODE

” and restore the LED to MODE-AUTO and SET “ON” enabled. 

Press SET also to enable/disable the Anti-leakage and Max pump On functions. After selecting the function using the 
“MODE” button, enable it by selecting SET-ON, to disable it select SET-OFF. 
In “MANUAL” mode, the SET is used to switch the pump on or off, LED “On” or “OFF”.  
In automatic mode AUTO-MODE it is used to turn it “ON” or in standby “OFF”. 

PUMP ON

: indication that coincides with the motor running. 

 

 

9.2 Description of the functions 

9.2.1 Pump ON/OFF (AUTO MODE, MANUAL MODE) 

Cut out disabled 

 on inserting the plug after the test on the LEDs the pump switches on for 10 seconds. 

Cut out enabled 

 after the plug is inserted, the test is conducted on the LEDs for the first 3 sec (LED 0 indicates that the 

power is always On) and the “

AUTO MODE

” is set as default with the indicator “

ON

”. The pump will start working if the 

pressure is less than the CUT –IN value and the flow is less than the minimum cut-in flow. The pump will continue to 
operate as long as the pressure remains less than the CUT-OUT value, and will switch off when this value is reached, 
independently of the flow. 
 
While, if the “

MANUAL MODE

” is selected, by pressing once the “

MODE

”, the pump will start up if the “

ON

” LED lights up, 

otherwise, if “

SET

” is pressed, the pump will switch itself off and the “

OFF

” LED will light up. 

When the pump starts working, it will enter the PRIMING mode. 
NOTE: Make sure the instructions for installation have been followed and that the pump is filled completely with water. 

 

9.2.2 Priming phase

 

When the pump starts working, it will enter the priming mode, during this phase if there is no flow and pressure the motor 
will remain switched on for 3 minutes after which it will enter dry run alarm. But if flow and pressure are present during this 
phase, priming will be carried out and the pump will work normally. 

 

9.2.3 Alarms reset

 

When there is an alarm, the red indicator on “

ALARM

” lights up. The alarm is reset by pressing “

SET

” once; if the cause 

of the alarm is eliminated, normal operation continues, otherwise the pump will return to alarm condition. 

 

Summary of Contents for D-BOOSTi Series

Page 1: ...INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE GB INSTRUCTIONS POUR L INSTALLATION ET LA MAINTENANCE FR INSTRUCCIONES DE INSTALACI N Y MANTENIMIENTO ES INSTRU ES PARA A INSTALA AO PT...

Page 2: ...ENGLISH Pag 1 FRAN AIS Page 10 ESPA OL P g 20 PORTUGU S pag 29...

Page 3: ...1 2 3 4...

Page 4: ...leaning the NRV 8 12 TROUBLESHOOTING 8 FILLING THE EXPANSION VESSEL WITH AIR 9 13 GUARANTEE 9 WARNINGS Read all this documentation carefully before installation Take out the plug before any interventi...

Page 5: ...citor F 40 Capacitor Vc 250 Hydraulic data Max flow rate l min 57 Max head m 45 Max pressure bar 6 Max suction depth m 8 3min Range of use Type of cable SJTOW 16AWG Grade of motor protection IP X4 NEM...

Page 6: ...rmations or breakages It is always good practice to place the pump as close as possible to the liquid to be pumped The pump must be installed only in horizontal position The pipes must never have an i...

Page 7: ...t the mechanical seal is well lubricated and that the pump immediately starts to work regularly Dry operation causes irreparable damage to the mechanical seal 2 The filling cap must be screwed on accu...

Page 8: ...ges the LEDs light up and switch off accordingly Function Display configuration Set Alarm Reset Auto Mode ON Enabled OFF Disabled Manual mode ON Enabled OFF Disabled Anti leakage ON Enabled OFF Disabl...

Page 9: ...ntil the ON LED comes on To disable it press SET until the LED switches on to indicate OFF C SET selection button Selectable modes 1 Reset Alarms 2 Enable disable in MODE MAX_PUMP_ON ANTILEACKAGE 3 In...

Page 10: ...nabled if the condition is such that the pump works for more than 30 minutes it will stop and the ALARM light will flash This function is used to protect the installation if the valve is accidentally...

Page 11: ...manufacturer or his authorized customer support service or by an equally qualified party in order to prevent all risks FAULT CHECKS possible cause REMEDY 1 The motor does not start and makes no noise...

Page 12: ...lve of the boiler pump air until the pressure gauge indicates about 23 2 2 9 psi 3 Screw the protective cover back on 13 GUARANTEE Any modification made without prior authorisation relieves the manufa...

Page 13: ...valve 17 12 RECHERCHE PANNES 17 REMPLIR D AIR LE VASE D EXPANSION 18 13 GARANTIE 19 AVERTISSEMENTS Avant de proc der l installation lire attentivement toute la documentation Avant chaque intervention...

Page 14: ...bit max l min 57 Hauteur totale nominale max m 45 R sistance la pression bar 6 Profondeur max d aspiration m 8 3min Champ d utilisation Type c ble SJTOW 16AWG Degr de protection du moteur IP X4 NEMA...

Page 15: ...d formations ou les ruptures ll est toujours conseill de positionner la pompe le plus pr s possible du liquide pomper La pompe doit tre install e exclusivement en position horizontale Les tuyauteries...

Page 16: ...Cette op ration est fondamentale pour le parfait fonctionnement de la pompe et indispensable pour que le joint d tanch it m canique soit bien lubrifi Le fonctionnement sec provoque des dommages irr p...

Page 17: ...e syst me la pression change les LEDs s allumeront ou s teindront de cons quence Fonction Configuration cran R glage Reset Alarme Auto Mode Mode automatique ON Active OFF D sactive Manual mode Mode ma...

Page 18: ...erreur n appara tra la dur e de 30 minutes n est pas modifiable Cette fonction est utilis e pour prot ger l installation dans le cas d un oubli accidentel de robinet ouvert dans le cas d une rupture...

Page 19: ...ispositif sort automatiquement de l alarme de fonctionnement sec si un d bit et ou une pression sont constat s Si l alarme est restaur e voir 9 2 3 une nouvelle tentative sera effectu e pendant 40 sec...

Page 20: ...ont si pr sentes D visser le bouchon du filtre la main o u avec la cl fournie Extraire depuis le haut de l unit du filtre Rincer la cartouche sous l eau courante et nettoyer le tamis filtrant avec une...

Page 21: ...pompe s active et se d sactive trop souvent A Membrane du vase d expansion endommag e B La pression du vase d expansion est trop basse A Faire remplacer le r servoir pa r le service technique autoris...

Page 22: ...les d fauts imputables des vices de fabrication ou de mat riau utilis Le produit en garantie pourra tre discr tion soit remplac par un nouveau en parfait tat de fonctionnement ou r par gratuitement si...

Page 23: ...mpieza de la v lvula antirretorno VA 27 12 B squeda de aver as 27 LLENAR CON AIRE EL VASO DE EXPANSI N 28 13 Garant a 28 ADVERTENCIAS Antes de proceder con la instalaci n leer detenidamente esta docum...

Page 24: ...57 Altura de elevaci n m x m 45 Presi n m x bar 6 Profundidad m x de aspiraci n m 8 3min Campo de utilizaci n Tipo de cable SJTOW 16AWG Grado de protecci n del motor IP X4 NEMA 3 Clase de aislamiento...

Page 25: ...ni roturas Se considera una buena norma colocar la bomba lo m s cerca posible del l quido a bombear Hay que instalar la bomba s lo en posici n horizontal Las tuber as nunca deben tener el di metro in...

Page 26: ...las manos o con la herramienta adecuada suministrada Esta operaci n es de importancia b sica para que la bomba trabaje bien y adem s es indispensable para lubricar bien la junta estanca mec nica Esta...

Page 27: ...F inhabilitado Anti leakage ON habilitado OFF inhabilitado Pulse SET Cut in Aumenta Disminuye Cut out Aumenta Disminuye OFF inhabilitado Max pump on ON habilitado OFF inhabilitado Pulse SET B Bot n de...

Page 28: ...luz encendida indique OFF C Bot n de selecci n SET Modos que se pueden seleccionar 1 Reajuste Alarmas 2 Habilitar inhabilitar en MODE MAX_PUMP_ON ANTILEACKAGE 3 Aumentar par metros en MODE CUT_IN CUT_...

Page 29: ...de f brica inhabilitada Cuando est habilitada si la bomba se pone en marcha m s de 6 veces en 2 minutos se detendr y el error ser indicado por el destello lento del LED rojo en ALARM Solucione los pro...

Page 30: ...ula VA 5 con la herramienta suministrada de serie Quite la v lvula antirretorno VA y l mpiela si estuviera sucia fig 9 Ensamble las piezas en el orden inverso a la secuencia de desmontaje 12 B SQUEDA...

Page 31: ...En f brica se realiza una precarga es decir que en el primer arranque no es necesario realizar ninguna operaci n Para el llenado de aire se necesita una bomba de aire o un dispositivo de inflado de ne...

Page 32: ...o 36 11 2 Limpeza da v lvula de reten o NRV 36 12 Localiza o avarias 36 ENCHIMENTO DO VASO DE EXPANS O COM AR 37 13 GARANTIA 38 AVISOS Antes de fazer a instala o ler muito bem todo este documento Ant...

Page 33: ...Caudal m x l min 57 Altura manom trica m x m 45 Press o m x bar 6 Profundidade m x de suc o m 8 3min Campo de aplica o Tipo de cabo SJTOW 16AWG Grau de prote o do motor IP X4 NEMA 3 Classe de isolamen...

Page 34: ...es nem ruturas sempre boa norma posicionar a bomba o mais perto poss vel do l quido a bombear A bomba deve ser instalada exclusivamente em posi o horizontal As tubagens nunca devem ser de di metro in...

Page 35: ...instrumento fornecido Abrir ao mesmo tempo a tampa de respiro 2 para que o ar saia Esta opera o fundamental para o funcionamento perfeito da bomba indispens vel para que o empanque mec nico resulte b...

Page 36: ...7 psi Quando a press o no sistema se altera os indicadores luminosos acendem se ou apagam se Fun o Configura o do ecr Set Reset ao Alarme Auto Mode ON Habilita OFF Desabilita Manual mode ON Habilita O...

Page 37: ...o led correspondente fun o MAX PUMP ON se acender de seguida premir SET at o led ON se acender Para desabilitar premir SET at a luz acesa indicar OFF C Bot o de sele o SET Modos selecion veis 1 Reset...

Page 38: ...ser habilitada ou desabilitada Vem configurada de f brica em desabilitada Quando habilitada se houver a condi o e a bomba arrancar mais de 6 vezes em 2 minutos a bomba para e o erro indicado atrav s d...

Page 39: ...erior Enxaguar o copo com gua corrente e limpar o filtro com uma escova macia Voltar a montar o filtro seguindo as opera es no sentido oposto 11 2 Limpeza da v lvula de reten o NRV Fig 4 Desligar a al...

Page 40: ...superior 7 A bomba ativa se e desativa se com muita frequ ncia A Membrana do vaso de expans o danificada B A press o do vaso de expans o est demasiado baixa A Mandar substituir a membrana pelo servi...

Page 41: ...odos os defeitos de fabrico ou do material utilizado O produto em garantia poder ser discri o substitu do por um em perfeito estado de funcionamento ou reparado gratuitamente se cumpridas as seguintes...

Page 42: ......

Page 43: ......

Page 44: ...12 18 cod 60193257...

Reviews: