VOIP-500 Series Quick Installation Guide
Copyright 2010 Talk-A-Phone Co. All rights reserved.
Talk-A-Phone Co.
• 7530 North Natchez Avenue • Niles, Illinois 60714-3804
Page 3 of 6
Phone 773.539.1100 • Fax 773.539.1241 • [email protected] • www.talkaphone.com
All prices and specifications are subject to change without notice.
Talk-A-Phone, Talk-A-Lert, Scream Alert and WEBS are registered trademarks of Talk-A-Phone Co.
Figure 3. Installation of the ferrite core on the network cable
Local Power
1. If PoE is not available, connect 12 VDC (500-800mA), 24 VDC (300-500mA) or 24 VAC
(300-500mA), to the 2-
pin “Power Supply Input” removable connector plug to the, as
shown in the
Figure 2
. By default the phone is setup for 24 VDC/24 VAC power modes.
NOTE: Dedicated line regulated power supply required.
2. For 12 VDC power mode, place the internal jumpers on the two outermost terminals as
shown in
Figure 4
.
3. For 24 VDC/ 24VAC power modes, place the internal jumper on the two innermost
terminals as shown in
Figure 4
.
Use a two conductor, No. 24 to 12 AWG cable size for power connections.