LIGHTNING PROTECTION
A lightning will usually penetrate the system through the long cables connected to it; therefore
all the long cables must be protected against lightning.
In the DREAM 2 there can be several cases where long cables will require lightning protection:
The DREAM++2W - the 2 wired line, can be kilometers long, the RS485 communication line
between the DREAM and remote interfaces can sometimes be very long and the DREAM AC
may also have long wires between the AC I/O boards and the solenoids. The lightning
protection is accomplished by adding special protection units between the cables coming from
the field and the device to be protected. The lightning protection circuits contain components
that react very fast when hit by a lightning. These components turn into a short-circuit that
leads the lightning energy into the ground. For this to happen, each lightning protection unit
must have a very good connection to the ground. In the 2W systems each RTU has a built in
lightning protection therefore it is very important not to forget the connection to the ground of
each RTU. The connection to the ground is done by a thick wire connected to a metal rod
inserted deeply into the ground.
The following pictures show the three types of lightning protection units- one that is used for
the 2W single cable system, the second that is used for protecting the RS485 communication
line, and the last one is for protecting the wiring that goes from the I/O AC board to the 16 AC
solenoids connected to it.