27
-
The next two screens show the statuses
of the digital and analog inputs. In the
digital inputs screen each closed contact
is marked with a
(+)
sign and an open
contact with
(-)
sign.
Analog inputs will appear with their
actual value. A
(-)
sign indicates
that the sensor is disconnected.
Following there are two screens
showing the flow rates of all the
water meters and all the
fertilizer meters in the
system.
The last status screen supplies information
about the status of communication with all
the RTUs used by the system. The type of
the RTU channel can be recognized by the
interface type appearing at the top left
corner: Int2W is the interface of a 2 wired
channel, IntRF is the interface for radio
channel. The channel address appears at
the top right corner.
RTUs with communication problem will be underlined. RF RTUs which are powered
by batteries may have a low battery status indicated by the letter
"B"
next to the
RTU number. Pushing
F3=Count
will turn the screen into an error counting screen;
2 wired
interface
List of RTUs
The interface
address is 2
Switching ON/OFF the
sound of the RTU
Switching ON/OFF the
Error count