Talboys Professional 1000RS Instruction Manual Download Page 5

C

ontrol

 P

anel

The front panel of the Incubating Rocking/Waving Shaker contains all the controls and 
displays needed to operate the unit.
a.  Standby button/standby indicator light: The standby indicator light will illuminate 

when the unit is plugged in. The unit will be in standby mode. Press the standby 
button to activate the temperature, speed/tilt angle and time functions. The standby 
indicator light will shut off and the temperature, speed/tilt angle and time displays 
will illuminate. Press the standby button again and the unit will once again be in 
standby mode.

B.    temperature  display:  Displays the actual/set-point temperatures in conjunction 

with the actual/set-point indicator lights. C. Up/down arrows for set-point control. 
On/off button starts/stops the heating function. D. The heat indicator light will be 
illuminated when the unit is heating.

E.        actual  indicator  light:  Illuminates when the temperature displayed is the actual

temperature of the air in the chamber.

F.  Set-point indicator light: Illuminates when the set-point temperature is displayed.

g.  Caution hot indicator light: Illuminates when the air temperature of the chamber 

is above 40°C (104°F).

H.  Speed/tilt angle display: Displays the speed and tilt angle of the unit. i. Up/down 

arrows for set-point control. On/off button starts/stops the rocking/waving function. 
J. The speed/tilt angle indicator light will be illuminated when the unit is rocking/
waving.

K.  Function button: Press to choose the function you are setting: speed or tilt.
L. Speed indicator light: Illuminates when the speed is displayed.
M. tilt indicator light: Illuminates when the tilt angel is displayed.
n.   time  display:  Displays accumulated time (continuous mode) or how much time is 

remaining (timed mode). The display range is from 0 to 9,999 minutes in one (1) 
second increments. The display will indicate minutes and seconds until the timer 
reaches 99 minutes and 59 seconds (99:59), then the display will automatically 
display minutes up to 9,999.

o. Up/down arrows for set-point control. On/off button starts/stops the time function.

l.

G.

K.

D.

a.

c.

B.

M.

I.

H.

n.

o.

F.

J.

E.

4

Summary of Contents for Professional 1000RS

Page 1: ...Instruction Manual Professional 1000RS Incubating Rocking Shaker Professional 1000WS Incubating Waving Shaker...

Page 2: ...____________________________________________________ Supplier ____________________________________________________________ Table of Contents Package Contents 1 Warranty 1 Installation 2 Maintenance Se...

Page 3: ...not use a cleaning agent or solvent on the front panel or lid which is abrasive or harmful to plastics nor one which is flammable Always ensure the power is disconnected from the unit prior to any cl...

Page 4: ...e a fire hazard Stop the unit immediately and do not operate until clean up is complete and vapors have dissipated motor brushes arc and may ignite flammable vapors Do not immerse the unit for cleanin...

Page 5: ...ure of the air in the chamber F Set point indicator light Illuminates when the set point temperature is displayed G Caution hot indicator light Illuminates when the air temperature of the chamber is a...

Page 6: ...or unbalanced loads Centered on tray Overall dimensions L x W x H 17 x 11 x 10 5 43 2 x 27 9 x 26 7cm Interior dimensions L x W x H 10 75 x 7 75 x 3 4 27 3 x 19 7 x 8 6cm Tray dimensions L x W 9 25 x...

Page 7: ...will turn off Professional Incubating Rocking Waving Shaker Operating Instructions Caution Hot Indicator The caution hot indicator light warns that the temperature of the air in the chamber is above 4...

Page 8: ...y until you reach the desired time b Start this function by pressing the on off button below the time display The unit will run for the selected time the up down arrows will become inactive while the...

Page 9: ...ently touching the tray while the unit is running the unit will display an E03 error message and automatically go to the horizontal home position and restart In the event of a mechanical obstruction t...

Page 10: ...Temperature sensor 380721 00 6 Lid 280309 00 7 Motor fan 120V 380731 00 230V 380732 00 8 Thermostat 380723 00 9 Front panel 385725 00 10 Circuit board 380736 00 11 Motor assembly 880535 00 12 Idler as...

Page 11: ...ure sensor 380721 00 6 Lid 280309 00 7 Motor fan 120V 380731 00 230V 380732 00 8 Thermostat 380723 00 9 Front panel 385727 00 10 Circuit board 380736 00 11 Motor assembly 880534 00 12 Idler assembly 8...

Page 12: ...tubes securely in place Mat can be easily removed for cleaning and transporting tubes from bench to tray Description Dimensions L x W Part Number Dimpled Mat Incubating Rocking Shaker 10 x 7 5 25 4 x...

Page 13: ...201 Wolf Drive PO Box 87 Thorofare NJ 08086 Phone 1 888 TALBOYS Fax 856 686 1601 E mail troemner troemner com www troemner com 715080 00 REV 9 5 15 Manufactured by...

Reviews: