background image

Symptoms

Possible cause

Remedy

Operation LED 

1. Disruption of power or inadequate power

1. Correct power source

does not light

2. Bad wiring connection or broken wire, short

2. Check and correct wiring

Receiver Alarm 

1. Disruption of power or inadequate power

1. Correct power source

LED does not

2. Bad wiring connection or broken wire, short

2. Check and correct wiring

light when the 

3. Reflection of beam is flooding receiver and 

3. Remove reflecting object. Set beam power to

beam is broken

sent into the receiver

Low. Contact TAKEX for further remedies

4. Four beams are not broken simultaneously

4. Ensure all beams are broken at same time

5. Beam interruption time is shorter than response time

5. Adjust response time

Receiver Alarm

1. Alignment is off

1. Check and adjust

LED stays on

2. Shading object between transmitter and receiver

2. Check site/remove any possible obstacles

3. Optics of units are soiled

3. Clean the optics with a soft cloth

4. Frequency channel setting on transmitter 

4. Readjust to be the same channel

does not match with that on receiver

Intermittent alarm

1. Bad wiring connection

1. Check again

2. Change of supply voltage

2. Stabilise supply voltage

3. Shading object between transmitter and receiver

3. Remove the shading object

4. The wiring of power machine is located nearby

4. Change the place for installation

transmitter and receiver

5. Stabilise

5. Unstable installation of transmitter and receiver

6. Optics of units are soiled

6. Clean the optics with soft cloth

7. Improper alignment

7. Check and re-adjust

8. Small animals may pass through the 4 beams

8. Change environments or the place for installation

9. Beam power switch is set at L, which does not 

9. Set beam power switch at H and make the unit 

keep enough sensitivity allowance

gain-locked with receiver cover detached 

Model

PB-IN-50HF

PB-IN-100HF

PB-IN-200HF

Detection System

Near infrared beam interruption system 
(TR. - RE. 4 beams simultaneous interruption)

Infrared beam

Double modulation pulsed beam by LED

Protection 

Outdoor 165’

Outdoor 330’

Outdoor 660’

distance

(50m) or less

(100m) or less

(200m) or less

Max. arrival 

Tenfold

Tenfold )

Tenfold 

distance

1640’ (500m)

3280’ (1000m) 6560’(2000m)

Summary of Contents for Quad PB-IN-50HF

Page 1: ...INDOOR 330 100m PB IN 100HF OUTDOOR 330 100m INDOOR 660 200m PB IN 200HF OUTDOOR 660 200m INDOOR 1320 400m INSTRUCTION MANUAL FEATURE The PB IN HF series beams are equipped with many features which pr...

Page 2: ...r receiver Avoid light in a direct path of 2 of optical axis Do not install in a site where beam may be interrupted by trees or plants consider seasonal changes Do not install the unit on unsteady sur...

Page 3: ...0m AWG18 1 00 1017 310m 9187 2800m 920 280m 8203 2500m 820 250m 7218 2200m AWG17 1 10 1246 380m 11156 3400m 1116 340m 9843 3000m 985 300m 8860 2700m AWG16 1 25 1640 500m 14765 4500m 1477 450m 13452 41...

Page 4: ...tach covers Break knockouts on cover and pole cover to adapt to pole diameter and configuration Grommet The grommet is compatible with a wire of 3mm to 6mm outer dia When a wire of more than 6mm outer...

Page 5: ...the beam Pre attach cover 5 Attach cover 1 Attach transmitter cover first 2 Confirm that receiver sensitivity attenuation LED stays OFF Place cover in position but do not secure A beep sound will occu...

Page 6: ...tacked protection This option allows field selection of the appropriate beam intensity relative to the application For distance significantly less than the specified protection distance the beam inten...

Page 7: ...ental signal is initiated if the beam reception level is reduced to approx 50 or more The module Watches for a gradual degradation of the beam reception which is indicative of extremely poor weather c...

Page 8: ...itter 4 Readjust to be the same channel does not match with that on receiver Intermittent alarm 1 Bad wiring connection 1 Check again 2 Change of supply voltage 2 Stabilise supply voltage 3 Shading ob...