background image

4.

Attach four U brackets to poles in two pairs, one on top of the other, 
facing opposite directions. 
(See illustration.)

(3) Pole mounting back to back.

Attach U brackets to pole and secure to mounting plate with 
screws.
Attach sensor body.
Pull through wire.
Connect terminals.
Attach covers. (Break knockouts on cover and *pole cover to adapt 
to pole diameter and configuration.)



Grommet

The grommet is compatible with a wire of ø3mm to ø6mm 
outer dia.
When a wire of more than ø6mm outer dia. is used, cut off 
the dotted line portion on the below figure by pliers or the 
like.
Do not fail to plug opening of wire hole to prevent insects 
from entering into the unit.

ø1.50" (ø38mm) inner
ø1.89" (ø45mm) outer

Grommet

U bracket

Knockout

Knockout

Knockout

*SOLD SEPARATELY

Summary of Contents for Quad PB-IN-50HF

Page 1: ...INDOOR 330 100m PB IN 100HF OUTDOOR 330 100m INDOOR 660 200m PB IN 200HF OUTDOOR 660 200m INDOOR 1320 400m INSTRUCTION MANUAL FEATURE The PB IN HF series beams are equipped with many features which pr...

Page 2: ...r receiver Avoid light in a direct path of 2 of optical axis Do not install in a site where beam may be interrupted by trees or plants consider seasonal changes Do not install the unit on unsteady sur...

Page 3: ...0m AWG18 1 00 1017 310m 9187 2800m 920 280m 8203 2500m 820 250m 7218 2200m AWG17 1 10 1246 380m 11156 3400m 1116 340m 9843 3000m 985 300m 8860 2700m AWG16 1 25 1640 500m 14765 4500m 1477 450m 13452 41...

Page 4: ...tach covers Break knockouts on cover and pole cover to adapt to pole diameter and configuration Grommet The grommet is compatible with a wire of 3mm to 6mm outer dia When a wire of more than 6mm outer...

Page 5: ...the beam Pre attach cover 5 Attach cover 1 Attach transmitter cover first 2 Confirm that receiver sensitivity attenuation LED stays OFF Place cover in position but do not secure A beep sound will occu...

Page 6: ...tacked protection This option allows field selection of the appropriate beam intensity relative to the application For distance significantly less than the specified protection distance the beam inten...

Page 7: ...ental signal is initiated if the beam reception level is reduced to approx 50 or more The module Watches for a gradual degradation of the beam reception which is indicative of extremely poor weather c...

Page 8: ...itter 4 Readjust to be the same channel does not match with that on receiver Intermittent alarm 1 Bad wiring connection 1 Check again 2 Change of supply voltage 2 Stabilise supply voltage 3 Shading ob...

Reviews: