Takex PR-30BE Instruction Manual Download Page 7

After mouting the sensor

and the reflector, wiring

and making the alignment

adjustment, check the

operation of the sensor with

its cover attached by looking

at the alarm LED.

※When setting tone indicator to “ON”,

    walk test mode starts 5 minutes after closing

    the cover, and pip sound comes out for alarm.

8

FUNCTIONS

Environmental output setting:

When the light reception level reaches the prescribed level or less for the

following reasons, the environmental contact output and LED will activate.

・Protection line obstructed due to growing trees and weeds

・Dirt on the surface of sensor cover and reflector

・Environmental deterioration caused by thick fog, blizzard, snow cover

・Incorrect alignment of optical axis of sensor and reflector, etc.

Be sure to wash the sensor cover only with water without wiping it

with a cloth.

In such cases, take appropriate measures like cutting trees,

cleaning the device, adjusting optical axes and so on,

so that the light reception is restored to the prescribed

level or more.

(Signal output continues min. 5 sec. until

the light reception is restored to the

prescribed level or more)

Sensitivity attenuation

/Environment LED : ON

It may take some time (max. a few minutes) for the environmental

output to recover even if the environment is restored. Press the

distance setting button for immediate recovery.

1 2 3 4 5 6

1

1

1 2 3 4 5 6

6

6

1 2 3 4 5 6

2

2

1 2 3 4 5 6

factory set

:0.05sec)

3 4

3 4

3 4

3 4

0.05sec.   0.1sec.     0.25sec.     0.5sec.

Wall, signboard, etc.

1 2 3 4 5 6

5

5

①Alarm output changeover

    (Function setting switch: DIP 1)

    N.C. or N.O. can be selected

    for alarm output logic.

N.C. (Factory set)

N.C.

N.O.

N.C.

N.O.

②Environmental output changeover

    (Function setting switch: DIP 2)  

    N.C. or N.O. can be selected

    for environmental output logic.

③ Response time adjustment  (Function setting switch: DIP 3/4)

     The detectable interruption time can be selected.

       (Refer to the diagram below to adjust the response time.)

<Caution>

・If the interruption time is shorter than the response time, there is no

    detection of obstructing object.

・If there is a possibility that large flying objects (birds, falling leaves, etc.)

    shield the optical axis, set the response time longer, considering the

    installation conditions.

Detection mode changeover

Select "Normal" mode (factory set) as regular setting.

This device is designed to emit an infrared beam from the

sensor body, monitor the change in the amount of light

returning from the reflecting object and the change in the

distance to the reflecting object

and output an alarm signal when

they exceed the prescribed value.

In "Normal" mode, lost alarm

caused by light wraparound

can be prevented by monitoring

these two changes.

However, when the environment suddenly changes in a short period

of time (such as concentrated torrential rain, rapid thick fog or snowstorm), 

the amount of light reflected and returned may change so suddenly

that an alarm signal is output.

④ Tone Indicator (Function setting switch : DIP 5)

     When tone indicator switch is ON, reception level is notified with sound.

     (Only when Monitor output switch is set to “Reception”)  

・As the light reception level increases, the sound changes from

     intermittent tone to continuous tone, and the pitch increases after that.

・This function operates only when the sensor cover is removed.

Tone Indicator

   : ON

Also, when selecting "ON", walk test mode starts after closing of the cover.

Walk test mode

       For 5 minutes after closing the cover, a pip sound is emitted when 

       crossing the protection line, for easy operation check. 

       (It automatically stops after 5 minutes)

       To extend the time for another 5 minutes, open the cover and close it

       again. Repeat this action to extend the time further. 

⑤Detection mode changeover

    (Function setting switch : DIP 6)

    Depending on the environment

    of the installation location, 

    "Normal" or "Harsh" can be

    selected.

Select "Normal" mode (factory set) as regular setting.   When setting to

"Harsh", read the section of 【Detection mode changeover】below 

carefully and fully understand the content before use.

Harsh

Normal

⑥Monitor output

    "Distance" or "Reception" can be selected when adjusting the optical axis

    using a test meter.    When set to "Distance", you can check the distance to

    the reflector.   Use it when there are reflective objects near the protection 

     line.

Distance

Reception

※Refer to “

7  OPTICAL AXIS ADJUSTMENT

” for further detail.

9

OPERATION CHECK

Alarm LED is ON

Function setting switch

Function setting switch

Function setting switch

N.C. (Factory set)

Function setting switch

Function setting switch

Run at full speed

Walking normally

Walking slowly

Response : 0.05 sec.

Response : 0.25 sec.

Response : 0.5 sec.

OFF (factory set)

Normal (factory set)

OFF

ON

Monitor output switch :

“Reception”

If this happens occasionally, set the detection mode to "Harsh" mode. "Harsh"

mode monitors only the change in the distance to the reflecting object, which

makes it difficult for a false alarm signal to be output even if there is a sudden

change in the environment.

※”Environmental output” is output regardless of detection mode.
On the other hand, in the "Harsh" mode, wraparound of the light may not be 

prevented. Recheck the operation, such as whether the alarm signal is always 

output when crossing the protection line, and start operating the device.

Beam on protection line

Beam reflected

on objects

pip

① Make sure that the alarm LED is off (in alarm condition)

     and confirm that there is nothing to block the infrared light.

② Cross the infrared light in various places on the

     protection line and check the operation. Confirm that

     the alarm LED is ON (alarm condition).

③ The device is operating normally if the alarm LED

     changes from ON (alarm) to OFF (protection) when

     you cross the infrared light.

④ Check also the operation of the connected system.

     Alarm is output during the light interruption time or for

     2 seconds when light is blocked for less than 2 seconds.

Summary of Contents for PR-30BE

Page 1: ...Flight technology consist of a sensor integrating both a transmitter and a receiver inside and a re ector As illustrated an infrared beam projected by the transmitter is re ected back to the receiver...

Page 2: ...them into the following categories As these are important be sure to read and strictly observe them Installation on uneven ground Installation in locations where the device may be splashed by dirty wa...

Page 3: ...1 7 to 100 ft INDOOR 0 5 to 40m 1 7 to 135 ft POSITION OF INSTALLATION INSTALLATION OF MULTIPLE SENSORS CAUTIONS ON INSTALLATION 80 to 100cm 31 to 39 PROTECTION DISTANCE HEIGHT OF INSTALLATION Center...

Page 4: ...just them to each center 127mm 5 58mm 2 28 Hood xing screw Self tapping screws Note In case of outdoor installation please do not remove hood POLE MOUNTING Follow the same procedure as wall mounting f...

Page 5: ...iable operation Make sure that angle remains within 15 even if angled installation is needed When exceeding this the amount of re ected light will be insu cient and it will not operate correctly Lens...

Page 6: ...ossible For more accurate adjustment insert a test meter into the monitor jack and check the voltage As a guide the monitor voltage is shown in the above table However adjust the sensitivity to as hig...

Page 7: ...mount of light re ected and returned may change so suddenly that an alarm signal is output Tone Indicator Function setting switch DIP 5 When tone indicator switch is ON reception level is noti ed with...

Page 8: ...e ector Resin clear black REFLECTOR SENSOR Do not clean the cover with a cloth Daily check Do not clean the cover with a cloth Check the operation of the unit once a week If the cover becomes soiled w...

Reviews: