WIRING

FUNCTION

TAMPER

VACANT L/C

1

2

3

4

5

6

7

8

POWER

ALARM

Power

Signal Input

Sensor

(N.C.)

Sensor

(N.C.)

■MODE SELECTOR

Switch

ON

OFF

Factory set

ALARM LED

The  alarm  LED  will  light  up,  synchronized  with  the 

alarm contact, if you set the mode selector at ON.

Switch3

ON

N.O.

OFF

N.C.

(Factory set)

ON  

N.O.

OFF

N.C.

ALARM CONTACT CHANGEOVER

Change alarm contact to N.O. when sensor is used for 

an  application  other  than  security  purpose,  such  as 

light control. 

SETTING OF SENSITIVITY

ON

OFF

120

100

Factory set

80

60

Switch

4・5

When operation check resultin excessive or insufficent high sensitivity of sensor, 

change setting of sensitivity 

with mode selector and 

re-check operation.  

Four settings are available.

ON  

LONG

OFF

WIDE

Switch6

ON

LONG

OFF

WIDE

(Factory set)

PROTECTION PATTERN CHANGEOVER

Two  protection  patterns  (Wide  angle/Long  range)  are  selectable  by  replacing  lens. 

Reselect the dip switch when exchanging lens (refer 

to  “3.  DETECTION  AREA”).  Do  not  set  the  switch 

OFF for long range protection. 

FACTORY SET

ON

OFF

1 2 3 4 5 6

■Terminal Arrangement

■Basic connection

■WIRING DISTANCE BETWEEN SENSOR AND POWER SOURCE

When this setting is "ON", memory is always stored 

when sensor is armed.

When an alarm has been activated, the memory LED 

flashes for 3 min. and then remains lit for 47 min.  

It automatically reset and memory is also canceled.

ALARM MEMORY CHANGEOVER 

Memory LED will inform you which sensor initiated an alarm during alert conditions when 

two or more sensors are connected on the same line. 

ON

Factory set

Switch

OFF

NOTE : Same LED is used to indicate alarm and alarm memory.

POWER 

(non-polarity)

9.5V to 28V DC

25mA Max.

Distance at 12VDC

Distance at 24VDC

Size of wire used

2500ft (  750m)

14000ft (  4400m)

4600ft (1400m)

28000ft (  8500m)

AWG 22 (Dia.0.65mm)
AWG 18 (Dia.1.0mm)
AWG 16 (Dia.1.25mm)

8500ft (2600m)

50000ft (15200m)

[When two units are used]

Note : 1) 

2)

Allow approx. one minute for warm-up after power is supplied.  

(Alarm LED is flashing)  In the meantime, no alarm is initiated.

After the one minute has passed, the unit will be in the armed 

condition and will trigger an alarm when detecting a human 

body.

Maximum wiring distance, when two or more sets are connected, is 

the value above divided by numbers of sets.
The signal line can be wired to a distance of 3,280 ft (1,000m) with 

AWG 22 (0.65mm dia.) wire.

Sensor operation can be adjusted to fit the environmentals / applications with the built-in mode selector.

ALARM OUTPUT

Dry contact (semi-conductor)

N.C./N.O. selectable

Reset : approx. 2 sec.

30V DC (24V AC) 0.25A Max.

(Protective resistor 3.3Ω)

VACANT

LED Control

(Refer to section “6.FUNCTION”)

TAMPER OUTPUT

Dry contact N.C.

Operation : Open when cover is detached.

30V DC 0.1A Max.

LED CONTROL

LED can be remotely controlled from the control panel. Even after setting 

alarm  LED  OFF,  combined  use  of  alarm  LED  control  terminal  (6  LED 

Control) and power terminal (negative) enables to reset the mode back to 

alarm  LED  ON,  which  makes  it  easy  to  operate  a  walk  test  even  after 

installation of the sensor. 

Alarm LED is lit by switching ON

CONTROLLER 

POWER

SENSOR 1

SENSOR 2

Set alarm LED OFF

OPERATION CHECK

NOTE : 

2 : Low voltage

TROUBLE ALARM

NOTE : 

1 : Unit trouble

This function checks / monitors sensor unit itself in accordance with built-in 

program.

When trouble is found out as a result of the check / monitor, alarm LED lights 

and an alarm signal also continuously outputs. 

Trouble alarm outputs when inner circuit / wiring is damaged / broken.  

See "8. TROUBLESHOOTING" and remedy table. 

The monitor functions regardless of mode settings but an alarm is 

not indicated in case of setting alarm LED at OFF position. 

When power is reset during the alarm status, trouble alarm stops 

only for warming up time.  

When  power  voltage  of  sensor  drops  down  (approx.  8.5V  DC  or  less), 

trouble alarm outputs before sensor operation becomes unstable due to low 

voltage.  See "8. TROUBLESHOOTING" . 

The monitor functions regardless of mode settings but an alarm is 

not indicated in case of setting alarm LED at OFF position. 

When  power  voltage  recovers  to  normal  level  during  the  alarm 

status, trouble alarm stops.

When installation is completed, turn the power "ON" and check operation after about 1min. warming up time, as follows:
1. Make sure that alarm LED finished flickering.

2. Make a walk test in the protected area to check if an alarm is initiated.

    Check alarm LED and control panel for sensor operation.  

3. After correct operation has been confirmed, use the mode selector 

    switch to disable the alarm LED, if required. 