background image

9

SPECIFICATIONS

10

EXTERNAL DIMENSIONS

                  

         

Unit: inch (mm)

■Option : Ceiling/Wall mounting attachment : BCW-401

Model

Detection System
Coverage
Sensitive zone

Supply Voltage
Current consumption

Alarm output

Tamper output

LED(Red)

LED control

Trouble signal

Ambient

temperature range
Mounting position
Wiring connections

Weight

Appearance

PA-470L

    

Passive infrared  (QUAD

Fuzzy logic)

    Wide angle protection

           52.5’ (16m) 

          88 (22pairs)

9.5 to 28V DC

non-polarity

  25mA Max.

   

N.C.

N.O. selectable

Dry contact (Semi-Conductor)

    

Reset : Apporox, 2 sec. (N.C./N.O. selectable)

24V DC (30V AC)  0.25A Max.   (protective resistor 3.3

Ω)

   Dry contact (type N.C.)

   

   Open when cover is detached

   30V DC   0.1A MAX.  (protective resistor 3.3

Ω)

Alarm LED

  

Flickering (every 0.5 sec.)   : Warming-up

Lighting   (approx. 2 sec.)    : Alarm

Flickering (every 0.25 sec.) : Trouble indication

Continuous lighting             : Trouble alarm

(LED disabled except trouble indication)

Memory LED

 

Flickering : Memory activated

Lighting   : Memory indication

Controls alarm LED indication / with terminal L/C

 Unit trouble : Monitorring inner circuit and wiring damage 

Operation : Trouble alarm

 Low voltage trouble  : Monitoring low voltage

Operation : Trouble alarm

+14°F to +122°F  (without dewdrops)

(

10

〜+

50

℃)

Indoor (Wall/pillar)

      Ceiling mount is possible with optional attachment

 Terminals

 5.82oz (165g)

resin (White)

Long range protection

66’ (20m

8 (2pairs)

Limited Warranty :

TAKEX products are warranted to be free from defects in material and workmanship for 12 months from original date of shipment. Our warranty does not cover 

damage or failure caused by natural disasters, abuse, misuse, abnormal usage, faulty installation, improper maintenance or any repairs other than those provided 

by TAKEX. All implied warranties with respect to TAKEX, including implied warranties for merchantability and implied warranties for fitness, are limited in 

duration to 12 months from original date of shipment. During the Warranty Period, TAKEX will repair or replace, at its sole option, free of charge, any defective 

parts  returned  prepaid.  Please  provide  the  model  number  of  the  products,  original  date  of  shipment  and  nature  of  difficulty  being  experienced. There  will  be 

charges rendered for product repairs made after our Warranty Period has expired.

In Japan

Takex America Inc.

4/15 Howleys Road, Notting Hill,

VIC, 3168

Tel  : +61 (03) 9544-2477

Fax : +61 (03) 9543-2342

Takenaka Engineering Co., Ltd.

83-1, Gojo-sotokan, 

Higashino, Yamashina-ku, 

Kyoto 607-8156, Japan 

Tel  : 81-75-501-6651

Fax : 81-75-593-3816

http : // www. takex-eng. co. jp /

Takex America Inc.

3350, Montgomery Drive,

Santa Clara, 

CA 95054, U.S.A

Tel  : 408-747-0100

Fax : 408-734-1100

http : // www. takex. com

Takex Europe Ltd.

Takex House, Aviary Court, Wade Road,

Basingstoke, Hampshire. RG24 8PE, U.K.

Tel  : (+44) 01256-475555

Fax : (+44) 01256-466268

http : // www. takexeurope. com

In the U.S.

In the U.K.

In Australia

COVER LOCKING SCREW

WIRING HOLE

1.44”(36.5)

3.74”(95)

3”(76)

3.33”(83.5)

3.54”(90)

5”(127)

2.46”(62.5)

φ0.16 (φ

4) 

HOLE

TROUBLESHOOTING

8

Completely inactive

Trouble

Check

Corrective Action

Sometimes inactive

Activated when 

no person has passed

Alarm LED lights, 

but connected devices

are inactives

(1) Connect wiring correctly, or repair problem wire

(2) Check terminal connection with a tester, etc

(3) Readjust setting of alarm output.

(4) Check connected devises

Alarm LED continues lighting or 

blinking and alarm output doesn’t 

stop. (Abnormal detection)

(1) Reset power supply and wait for warm-up to be done.

(1) Contact the dealer or TAKEX

(Devise or wire may be broken inside)

(1) Improper detection area settings (including detection distance).

(2) Improper function mode setting.

(3) Detection lens is covered with dust or water droplets.

(4) Small difference between human and ambient temperature

(1) Readjust detection area.

(2) Readjust mode setting.

(3) Clean the lens with soft and dry cloth.

(4) Increase sensitivity up to 120% 

(1) Unstable power supply voltage.

(2) Something is moving within the detection area, or there are sudden 

      changes in temperature.

(3) A source of electrical noise (broadcasting station, amateur radio station, 

      etc.) is nearby.

(4) Strong light (direct or reflected) such as sunlight or headlights from 

front side of the detection area.

(5) Detecting someone passing outside the detection area.

(6) Movement of pets is detected

(7) Movement of robot cleaners is detected 

(1) Supply appropriate power voltage.

(2) Remove problem object.
(3) Change mounting location.
(4) Change mounting location or shield light with blinds, etc.
(5) Readjust detection area.

(6) Prevent pets from entering detection area.

(7) Prevent robot cleaners from entering detection area.

(1) Power supply is not connected(including broken wiring).

(2) Power supply voltage is low.

(3) 1 minute has not passed yet since turning the power ON.

(4) The detection area is blocked by obstacles (which may include glass).

(5) Improper detection (including detection distance).

(6) Improper function mode setting.

 

(1) Check the power wiring. 

(2) Supply appropriate power voltage.

(3) Wait approximately 1 minute.

(4) Remove obstacles.

(5) Readjust detection area.

(6) Readjust mode setting.

MAINTENANCE

Analyze possible problems according to the following table. If normal operations cannot be restored by 

these means, contact either the dealer from whom you bought the unit or TAKEX.

To clean the device, use a soft, wet cloth and then wipe off any water drops. If the device is particularly dirty, dip the soft cloth in the water that contains a weak 

neutral detergent. Wipe the device gently with the cloth, then wipe off any detergent that remains.  Do not use substances such as thinner or benzene. 

(The plastic parts may deform, discolor or change their properties.)  

Perform operation checks on a regular basis.

(1) Wiring failure, broken wire, or short-circuit

(2) Alarm signal is not output.

(3) Setting of alarm output is inappropriate. 

(4) Connected devices don’t function normally.

Specifications and design are subject to change without

 prior notice.

2

0

21.8.26

Reviews: