Caution

Passive infrared sensors are designed to detect changes of 

far-infrared ray energy. Energy changes largely when the human 

body moves across the detection area. However, energy does not 

change so much when the human body 

comes closer in a straight line, or stops.

In addition, if the environment of detection 

area generates similar changes due to certain 

factors, the unit will issue an alarm without 

being able to judge properly.

Avoid installing the unit in the following places. 

Otherwise, non-detection and/or false detection may occur.

• Places subject to strong direct or reflected light (sunlight, spotlight)

• Places subject to rapid temperature fluctuations (air outlets of 

air-conditioning equipment, etc.)

• Places where moving objects are included in the protection area 

(plants, laundry, etc.)

• Places subject to strong vibration and/or electric noise

• Places where pets, such as dogs and cats, and/or automatic 

cleaning robots may pass

• Places where shielding objects (including glass and transparent 

resin, etc.) are placed in the protection area (shading parts will not 

be detected)

• Places that people can easily touch.

Securely conduct installation work according to the instruction 

manual.

Also, make sure to use the supplied accessories and specified 

components.

Failure to follow this may result in injury and/or property damage in 

the event of fire, electric shock or fall of the unit.

Ask qualified personnel for any electrical work necessary for 

installation, if required.

Failure to follow this may result in fire and/or electric shock.

This unit is for indoor use. Do not use the unit in places subject  to 

water and/or high humidity. Failure to follow this may result in 

malfunction if water gets into the unit.

This unit is not a waterproof (moisture proof/rainproof) or dust-proof 

structure. Do not use the unit in places subject to water and/or high 

humidity, such as bathrooms, and/or subject to large amounts of 

dust or sand. Failure to follow this could result in malfunction.

Do not perform aerial wiring of power and signal cables. Failure to 

follow this may result in electric shock, fire, and/or malfunction.

3

DETECTION AREA

4

Pull  four  lens  tabs  on  back 

side of the cover toward inside 

and  push  them  out  to  remove 

the lens.

1.

Lens exchange

Put smooth face of the lens on 

the  front  side.  Push  one  side 

of  the  lens  into  one  side  slot 

of the cover until it snaps.

2.

Carefully  bend  the  lens  along 

edges of the cover. Push other 

side  of  the  tabs  into  the  other 

slot of the cover until it snaps.

3.

Set dip switch 

"

6

"

 of the mode 

selector to the mode 

corresponding to protection 

pattern of the lens (refer to 

section  6. FUNCTION )  

4.

8.3’

(2.5m)

52.5’

(16m)

49’

(15m)

33’

(10m)

16’

(4.9m)

0

36°

80°

84°

15.5°

[Top view]

[Side view]

WIDE ANGLE

LONG RANGE

66’

(20m)

49’

(15m)

33’

(10m)

16’

(4.9m)

0

3.3’

(1m)

80°

[Top view]

[Side view]

*

 Long range protection is possible with supplied long range lens. 

INSTALLATION

Loosen the cover locking screw and 

remove the cover. Do not remove the screw 

from the cover not to lose locking nut.

1.

For wall mounting, use wall mounting hole 

located in the center of the base. 

For corner mounting, break 4 knockouts on 

both side to use corner mounting holes.

2.

Break knockouts of wiring holes required 

to connect wires. In case wiring through 

upper wiring holes, pass the wires along 

wiring channels on either side of the 

base to connect them to the terminal.

3.

Attach the cover and tighten the cover 

locking screw.

4.

Plants/Curtain

Refrigerator

Shielding objects

Facing the window

Do not install the sensor directly on the ceiling 

(When installed on ceilling, use optional 

attachment BCW-401)

Reviews: