Caution
Passive infrared sensors are designed to detect changes of
far-infrared ray energy. Energy changes largely when the human
body moves across the detection area. However, energy does not
change so much when the human body
comes closer in a straight line, or stops.
In addition, if the environment of detection
area generates similar changes due to certain
factors, the unit will issue an alarm without
being able to judge properly.
Avoid installing the unit in the following places.
Otherwise, non-detection and/or false detection may occur.
• Places subject to strong direct or reflected light (sunlight, spotlight)
• Places subject to rapid temperature fluctuations (air outlets of
air-conditioning equipment, etc.)
• Places where moving objects are included in the protection area
(plants, laundry, etc.)
• Places subject to strong vibration and/or electric noise
• Places where pets, such as dogs and cats, and/or automatic
cleaning robots may pass
• Places where shielding objects (including glass and transparent
resin, etc.) are placed in the protection area (shading parts will not
be detected)
• Places that people can easily touch.
Securely conduct installation work according to the instruction
manual.
Also, make sure to use the supplied accessories and specified
components.
Failure to follow this may result in injury and/or property damage in
the event of fire, electric shock or fall of the unit.
Ask qualified personnel for any electrical work necessary for
installation, if required.
Failure to follow this may result in fire and/or electric shock.
This unit is for indoor use. Do not use the unit in places subject to
water and/or high humidity. Failure to follow this may result in
malfunction if water gets into the unit.
This unit is not a waterproof (moisture proof/rainproof) or dust-proof
structure. Do not use the unit in places subject to water and/or high
humidity, such as bathrooms, and/or subject to large amounts of
dust or sand. Failure to follow this could result in malfunction.
Do not perform aerial wiring of power and signal cables. Failure to
follow this may result in electric shock, fire, and/or malfunction.
3
DETECTION AREA
4
Pull four lens tabs on back
side of the cover toward inside
and push them out to remove
the lens.
1.
●
Lens exchange
Put smooth face of the lens on
the front side. Push one side
of the lens into one side slot
of the cover until it snaps.
2.
Carefully bend the lens along
edges of the cover. Push other
side of the tabs into the other
slot of the cover until it snaps.
3.
Set dip switch
"
6
"
of the mode
selector to the mode
corresponding to protection
pattern of the lens (refer to
section 6. FUNCTION )
4.
8.3’
(2.5m)
52.5’
(16m)
49’
(15m)
33’
(10m)
16’
(4.9m)
0
6°
36°
80°
84°
15.5°
[Top view]
[Side view]
WIDE ANGLE
LONG RANGE
66’
(20m)
49’
(15m)
33’
(10m)
16’
(4.9m)
0
3.3’
(1m)
80°
[Top view]
[Side view]
*
Long range protection is possible with supplied long range lens.
INSTALLATION
Loosen the cover locking screw and
remove the cover. Do not remove the screw
from the cover not to lose locking nut.
1.
For wall mounting, use wall mounting hole
located in the center of the base.
For corner mounting, break 4 knockouts on
both side to use corner mounting holes.
2.
Break knockouts of wiring holes required
to connect wires. In case wiring through
upper wiring holes, pass the wires along
wiring channels on either side of the
base to connect them to the terminal.
3.
Attach the cover and tighten the cover
locking screw.
4.
Plants/Curtain
Refrigerator
Shielding objects
Facing the window
Do not install the sensor directly on the ceiling
(When installed on ceilling, use optional