3) Wall mount
4) Pole mount
5) Pole mounting back to back.
①
Make holes in the wall.
・
Place the mounting plate the wall as a template for drilling
and mark the screw holes. (Allow a space of 1" (25mm)
above and below the plate.
This will provide easy detachment of the cover after
installation.)
②
Install the sensor.
・
Insert tapping screws to 0.59" (15mm) under the screw head.
・
Install the mounting plate on the wall after pulling the wire
through it.
・
Connect terminals.
・
Attach sensor cover.
②
Install sensor on the pole.
・
Attach the U brackets to pole and fix the mounting plate
with screws.
・
Fix the sensor the body to the mounting plate.
・
Connect the terminals.
・
Attach the sensor and pole covers.
(Break the knockouts on the cover and pole cover to adapt
to pole's diameter and configuration.)
・
Attach the two U brackets to
the poles, one on top of the
other, facing opposite
directions.
(See illustration.)
①
Make a wiring hole in the pole. Pull
the wire through wire.
Wood
φ0.12"
φ3mm
Concrete
Use plug etc.
1) Supply power with covers off.
2) Look through the view finder on the transmitter unit and move it until
the receiver unit is visible.
Repeat the procedure on the receiver unit.
3) Set the adjustment mode switch on the receiver to "adjustment mode".
Connect the digital volt meter to the monitor jack and check the monitor
output voltage (beam reception level).
When the output voltage is low, adjust the installation height of the
transmitter and receiver so that the output voltage will reach the
highest level. (Make sure that the angle of the antenna does not change.)
4) After adjustment, make sure that the adjustment switch is set to
"Operation mode".
1" (25mm) or more
1" (25mm) or more
0.59" (15mm)
2) Check by both the alarm LED and control panel
1) Check by alarm LED only.
After the installation and angle adjustment are
finished, test operation by performing a walking
test throug walk testing the sensor.
Two methods may be used.
*
The grommet is compatible with a wire of
φ
0.12" (
φ
3mm)
to
φ
0.24" (
φ
6mm) outer diameter.
When a wire of more than
φ
0.24" (
φ
6mm) outer dia.
is used, cut off the dotted
line portion as illustrated
using pliers or the like.
Then use caulking to
prevent insects from
entering into unit.
Grommet
4
OPERATION CHECK
3
SET-UP OF FUNCTIONS AND
ALIGNMENT
③
After adjustment, set the adjustment mode switch to "Operation mode".
・
Pre-drill in wall.
Concrete wall : Refer to specifications of the securing plug used.
Wooden wall : 0.12" (3mm) diameter.
Voltage reading
2.1V or more
1.8V to 2.1V
1.8V or less
Sensitivity
Best
Good
Poor, re-adjust
Digital voltmeter
Vertical angle
adjustment screw
Adjustment dial
Antenna
Install the sensor at a proper height and position otherwise detection
area could be widened over 6.6' (2m).
This could cause the sensor to detect movements of cars or vegetations
near the area and lead to frequent false alarms.
Note:
(Option)
When cover is attached, the sensor is switched
to be in an operation mode automatically.
Note:
φ1.77" (φ45mm)
φ1.50" (φ38mm)
Knockout
RE
TR
Light
Control panel
RE
TR
Light