background image

3) Wall mount 

4) Pole mount 

5) Pole mounting back to back. 

Make holes in the wall.

Place the mounting plate the wall as a template for drilling 

and mark the screw holes. (Allow a space of  1" (25mm) 

above and below the plate.

This will provide easy detachment of the cover after 

installation.)

Install the sensor.

Insert tapping screws to 0.59" (15mm) under the screw head.

Install the mounting plate on the wall after pulling the wire 

through it.

Connect terminals.

Attach sensor cover.

Install sensor on the pole.

Attach the U brackets to pole and fix the mounting plate 

with screws.

Fix the sensor the body to the mounting plate.

Connect the terminals.

Attach the sensor and pole covers.

 (Break the knockouts on the cover and pole cover to adapt 

to pole's diameter and configuration.)

Attach the two U brackets to 

the poles, one on top of the 

other, facing opposite 

directions. 

    (See illustration.)

Make a wiring hole in the pole. Pull 

the wire through wire. 

Wood

φ0.12"

φ3mm

Concrete

Use plug etc.

1) Supply power with covers off.

2) Look through the view finder on the transmitter unit and move it until 

the receiver unit is visible.

    Repeat the procedure on the receiver unit.

3) Set the adjustment mode switch on the receiver to "adjustment mode".

    Connect the digital volt meter to the monitor jack and check the monitor 

output voltage (beam reception level).

        When  the  output  voltage  is  low,  adjust  the  installation  height  of  the 

transmitter  and  receiver  so  that  the  output  voltage  will  reach  the 

highest level. (Make sure that the angle of the antenna does not change.)

4)  After  adjustment,  make  sure  that  the  adjustment  switch  is  set  to 

"Operation mode".

1" (25mm) or more

1" (25mm) or more

0.59" (15mm)

2) Check by both the alarm LED and control panel

1) Check by alarm LED only.

After the installation and angle adjustment are 

finished, test operation by performing a walking 

test throug walk testing the sensor.

Two methods may be used.

The grommet is compatible with a wire of 

φ

0.12" (

φ

3mm) 

to 

φ

0.24" (

φ

6mm) outer diameter. 

   When a wire of more than 

φ

0.24" (

φ

6mm) outer dia. 

is used, cut off the dotted 

line portion as illustrated   

using pliers or the like. 

Then use caulking to 

prevent insects from 

entering into unit. 

Grommet

4

OPERATION CHECK

3

SET-UP OF FUNCTIONS AND 

ALIGNMENT

After adjustment, set the adjustment mode switch to "Operation mode". 

Pre-drill in wall.

    Concrete wall : Refer to specifications of the securing plug used.

    Wooden wall : 0.12" (3mm) diameter.

Voltage reading
2.1V or more
1.8V to 2.1V
1.8V or less

Sensitivity

Best

Good

Poor, re-adjust

Digital voltmeter

Vertical angle 

adjustment screw
Adjustment dial

Antenna

Install  the  sensor  at  a  proper  height  and  position  otherwise  detection 

area could be widened over 6.6' (2m).

This could cause the sensor to detect movements of cars or vegetations 

near the area and lead to frequent false alarms.

Note:

(Option)

When  cover  is  attached,  the  sensor  is  switched 

to be in an operation mode automatically.

Note:

φ1.77" (φ45mm)

φ1.50" (φ38mm)

Knockout

RE

TR

Light

Control panel

RE

TR

Light

Reviews: