140
MAINTENANCE
Replacing the Air Cleaner
Element
WARNING
Stop the engine and allow the machine to
cool down before performing maintenance.
¡
¡
¡
¡
¡
The engine, muffler, radiator and many
other parts of the machine are hot
directly after the engine is stopped.
Touching these parts will cause burns.
IMPORTANT: Do not use an element if its
flutes, gaskets or seals are damaged.
Supplement: Do not remove and clean the
inner element (option). Replace the inner
element every 1000 hrs. or after every 3
cleaning of the outer element.
(whichever comes first)
< TB153FR >
< TB180FR >
1. Open the engine hood.
2. Loosen the clamp (1) and remove the dust
cup (2).
3. Clean the inside of the dust cup (2).
4. Remove the element (3).
5. Cover the intake hole at the back of the
body (4) with cloth or tape to prevent dirt
from getting in.
< If equipped with the inner element >
Do not yet remove the inner element (5).
6. Clean the inside of the body (4).
7. Remove the cloth or tape applied in step 5.
< If equipped with the inner element >
Remove the inner element (5).
8. Install the new elements.
9. Install the dust cup (2) with the “TOP” mark
at the top, then fasten it with the clamp (1).
Every 1000 Hours
Summary of Contents for TB153FR
Page 6: ...4...
Page 8: ...6...
Page 45: ...43 MEMO...
Page 68: ...66...
Page 89: ...87 MEMO...
Page 108: ...106...
Page 180: ...178 SPECIFICATIONS Machine Dimensions...
Page 182: ...180 SPECIFICATIONS Operating Range J1K0021 D J H K C F G A E B...
Page 184: ...182 MEMO...
Page 194: ...192...
Page 225: ...223 MEMO...
Page 230: ...228...
Page 231: ...229 INDEX...