■Items that must be inspected after closing for the day
Inspection item
Inspection method
If the inspection results show defects
□Is the drain blocked?
□Check that the drain is not blocked
with the drain cap, towel or
shampoo cloth.
□Remove the object that is blocking the drain. If the
drain is blocked, water that is turned on
accidentally or a slight trickle of water due to an
increase in water pressure at night may cause
water to spill from the basin, leading to water
leakage.
□Has the water control
knob been closed
firmly?
□Close the water control knob firmly
and check that the water turns off
properly.
□Close the water control knob firmly and turn the
water off properly. If the water does not turn off
completely, there may be a malfunction of the
fauset. Close the stop valves in the water supply
pipe and hot water supply pipe, and stop using the
product immediately. (Refer to pages 20. )
Inspection item
Inspection method
If the inspection results show defects
□Can the basin be
filled with water?
□Check that the drain cover can
block the drain when turning it
over, and water filling in the basin
does not drain.
□When the water decreases quickly, there is a
possibility that the drain cap packing has
deteriorated. The drain cap packing is a
consumable part. For replacement, contact the
nearest dealer of Takara Belmont dicreclty.
□Has the neck cushion
degraded?
□Check that there is no tearing, dirt
or sinking of the neck cushion
surface.
□These may cause pain or transfer dirt to the
customer's neck and head. The neck cushion is
consumable supplies. Replace it as soon as
possible.
Inspection item
Inspection method
If the inspection results show defects
□Is there any water
scale or dirt blocking
the sprinkling filter
unit?
□Remove the sprinkling filter unit
from the showerhead and check
that there is no water scale or dirt
on it. (Refer to pages 19.)
□Use an item such as a toothbrush to remove any
dirt such as water scale, and clean the sprinkling
filter unit. Leaving the sprinkling filter unit unclean
will lead to blockage, and water may not be output
from the showerhead properly.
■Items that must be inspected once each week
□Is there any water
leakage from the
drain hose?
□Remove the unit rear cover and
check that there is no water leaking
from the drain hose (see page 20).
□If water is leaking from the drain hose, the drain
hose may be worn, degraded or damaged.
Immediately stop using the product and contact
the nearest dealer or Takara Belmont directl
□Is there any water
leakage inside of the
basin unit?
□Remove the unit rear cover and
check that there is no water leaking
from the internal pipes or water
taps (see page 20).
□If water is leaking from the pipes, the pipes and
packing may be worn, degraded or damaged.
Close the stop valves in the water / hot water
supply pipes (Refer to pages 24 to 26),
immediately stop using the product, and contact
the nearest dealer or Takara Belmont directly.
27