background image

□Does the temperature 

control knob work 

properly?

□Turn the temperature control knob, check 

that the water temperature is adjusted 

properly and that there is no abnormal 

sound. 

* An abnormal gushing sound may be 

emitted as water flows. 

(Refer to page 11.)

□If the water temperature cannot be adjusted 

properly or if there is abnormal sounds, there may 

be a problem with the thermostat inside of the 

basin unit. S top using the product immediately, 

and contact the nearest dealer or Takara Belmont 

directly.

26

Procedures for Daily Inspections

To ensure that this product can be used for a long period of time, conduct the inspections below.
When repair is necessary, contact the nearest dealer or Takara Belmont directly.

■Inspect the product every day

Inspectionitem

Inspection method

If the inspection results show defects

□Is the basin unit not wet 

with water?

□Check if the parts except inside of the 

basin is not wet.

□It may cause malfunction of the product, or stain 

may become hard to remove.

Immediately wipe away the moisture adheres on 

the parts except inside of the basin.

□Is the mounting surface of 

the basin unit not wet with

water?

□Visually check the mounting surface of 

the basin unit and check it is not wet with 

water.

□There is a possibility that water is leaking inside of 

the basin unit. Open the maintenance cover and 

check inside (Refer to pages 20.). 

If water is leaking from the pipes, immediately stop 

using the product, contact the nearest dealer or 

Takara Belmont directly.

□Does the water control

knob work properly?

□Turn the water control knob and check if 

warm water is output properly and that 

there is no abnormal noise, then close 

the water control knob and check that

warm water stops properly.

□If there is abnormal noise or the water does not

turn off properly when the water cotrol knob is

closed firmly, there may be a malfunction of the

fauset.

□Is water output from the 

showerhead properly?

□Turn on the tap, and visually check that 

water is discharged normally from the 

showerhead, water is not leaking from 

the air bubble unit, or the hot water is 

not turbid.

□If water is leaking from the air bubble unit or from the 

base of the showerhead, the internal packing may be 

worn out. If replacement is required, contact the nearest 

dealer or Takara Belmont directly.

□If hot water does not come out normally, or it is turbid, 

there is a possibility that the filter of the check valve is 

contaminated. Clean the filter. (Refer to pages 20.)

□When a few water line splashes out of the water flows, 

there is a possibility that water scale or dirt may be 

contaminated in the sprinkling filter unit. Remove the 

sprinkling filter unit and clean it. (Refer to page 19.)

□Is the plating of the water 

control knob peeled off?

□Visually check the water control knob for 

flaws, cracks, or peeling of the plated 

surface.

□Flaws, cracks, or peeling of the plated surface may 

result in injury of hand. If they exist, replacement 

of the knob is required. Contact your closest dealer.

□During operation or maintenance, check 

that there are no burrs or irregularities 

on the surface.

□Is there any hair/objects 

caught in the drain cap?

□Check if there is any hair/objects caught 

in the drain cap.

□Remove any hair/objects caught in the drain cap.

□Is there an abnormal

odor coming from the

basin drain?

□Check if there is an abnormal odor

coming from the basin drain

□Remove any hair and other objects trapped in the

hair catcher. (see page 18)

Summary of Contents for RS SWING

Page 1: ...Thank you for purchasing this Takara Belmont product The instructions contained in this booklet should be thoroughly read and understood before use Using this product before reading this operating ma...

Page 2: ...responsible for any damage or risk incurred Detailed descriptions of symbols are provided below Read and understand these symbols thoroughly before reading this manual Symbols If this symbol is ignor...

Page 3: ...cution fire or abnormal operation leading to injury Disassembly and repairs modifications are prohibited Return the temperature control knob to an appropriate position after using hot water Return the...

Page 4: ...rounding area and turn the water control knob slowly Do not drink the hot water This product is designed for washing hair Do not drink the hot water The water quality may cause diarrhea or stomach pai...

Page 5: ...sunlight or heat from a stove Avoid direct sunlight or heat from a stove Failure to follow this instruction may cause discoloration or degradation of the product Do not leave the showerhead immersed i...

Page 6: ...n may cause flaws on the surface or breakage of the neck cushion Set the water temperature for this product to 80 or less Failure to follow this instruction may cause malfunction or breakage in parts...

Page 7: ...nd the basin when the backrest is reclined may vary slightly from product to product 1 Back shampooing the user stands behind the basin and performs shampooing from the back back position 7 Position o...

Page 8: ...eel due to corrosion or aged deterioration Flaws or cracks may occur on the plated surface due to impacts from falling objects Flaws or cracks may occur on the plated surface when a hard object hits t...

Page 9: ...fixing pins are detachable Be careful not to lose them 3 While shaping the neck cushion along the basin edge secure the hooks of the neck cushion to the fixing pins on the outer side of the basin Cha...

Page 10: ...immediately stop using the product and contact the nearest dealer or Takara Belmont directly The drain pipe may be clogged with dirt resulting in water leakage of the inside of the product Operate th...

Page 11: ...or a lack of grease as a result of aging Replacement of the packing or other parts or a recoating of grease is required available at additional cost Caution 1 Turn the temperature control knob in the...

Page 12: ...osition of the temperature control knob is adjusted Note Caution Return the temperature control knob to an appropriate position after use Continuing to use the hot water with the knob in the hot tempe...

Page 13: ...slows there is a possibility that dust and dirt may have clogged the drainpipe Immediately stop using the product and contact your closest dealer To fill up basin with water 1 To accumulate hot water...

Page 14: ...s fully swung to its maximum until it stops moving and fixes Failure to follow this instructions may make the basin to move during shampooing causing leakage or wetting client s clothes 3 Adjust the s...

Page 15: ...ating shower head However water may drop to the floor depending on the shampooing way Please take note of the followings when performing shampooing 1 Do not touch the client hair with the shower head...

Page 16: ...fter shampooing raise the chair backrest while supporting the client s head by your hand Caution Always support the client s head by your hand when raising the chair backrest 6 Swing back the basin to...

Page 17: ...l nail polish remover gasoline or kerosene cleaning products such as wax with a scourer a sponge with a scourer detergents that include organic solvents acidic alkaline or chlorine based detergents or...

Page 18: ...shampoo Showerhead Holder Tap Temperature Control Knob Wipe off the dirt with a soft cotton or towel with detergent solution diluted using water Caution Even when using a sponge for home use continuou...

Page 19: ...Rotate and loosen the air bubble fixture with the wrench 3 Caution The air bubble unit should be rinsed with running water in the direction shown in the illustration below Running Water Air Bubble Un...

Page 20: ...ply pipe When removing maintenance cover and plumbing cover pay attention those parts will not hit the rotation arm cover 4 When the strainer is detached the water in the pipe will come out Therefore...

Page 21: ...n unit or pipes in the rotat ion arm may be damaged so contact the nearest dealer or Takara Belmont directly Stop Valve Knob Open the Stop Valve at the beginning of the day and close it at the end of...

Page 22: ...se Replace every three years For the drain hose there is a possibility that water leaks will occur because cracks are caused due to deterioration and hardening of the hose from chemical agents in the...

Page 23: ...rs Consumable Parts The following parts are not covered by the wa rranty the cost of replacement is your responsibility Drain cap Hair catcher Rubber gasket etc Air Bubble unit of showerhead air bubbl...

Page 24: ...ly pressure Difference between hot water supply pressure and water supply pressure Within 0 2 MPa 2kgf cm2 Operating environment Operating temperature 10 40 Operating humidity 95 or below No condensin...

Page 25: ...neck cushion 676 Shampoo basin mounting surface 977 497 428 887 650 90 52 470 951 885 325 522 228 Chair side Center of Drain pipes Center of rotation 922 639 228 162 400 600 Pitch 1200 112 5 Operating...

Page 26: ...at there is no abnormal noise then close the water control knob and check that warm water stops properly If there is abnormal noise or the water does not turn off properly when the water cotrol knob i...

Page 27: ...ion degraded Check that there is no tearing dirt or sinking of the neck cushion surface These may cause pain or transfer dirt to the customer s neck and head The neck cushion is consumable supplies Re...

Page 28: ...28 1E0511A0 1 1 2 Chome Higashi shinsaibashi Chuo ku Osaka Japan Printed in Japan TAKARA BELMONT CORPORATION TEL 06 6213 5945 FAX 06 6212 3680...

Reviews: