- 6 -
GENERAL
1.
The manifold gas pressure is preset at the factory.
It is computer controlled and should
not need adjustment.
2.
Maintain proper space for servicing.
Install the unit so that it can be connected or
removed easily. Refer to p. 7 and p. 9 for proper clearances.
3.
The electrical connection requires a means for switching off the power supply.
4.
If you will be installing the unit in a contaminated area with a high level of dust, sand,
flour, aerosols or other contaminants, they can become airborne and enter and build up
within the fan and burner causing damage to the unit. Particles from flour, aerosols, and
other contaminants may reduce the functions of the rotating fan and cause improper
burning of the gas. Regularly ensure that the area around the unit is dust- or debris-free;
regular maintenance is recommended for these types of environment.
5.
Do not install the unit where the exhaust vent/opening is pointing into any opening in a
building or where the noise may disturb your neighbors. Make sure the vent
termination/exhaust opening meets the required distance by local code from any
doorway or opening to prevent exhaust from entering a building (refer to p. 13).
ACCESSORIES
Check that the installation manual and the warranty card are included with the unit.