7.7. CHANGING THE HYDRAULIC SYSTEM OIL
• Change oil after 5,000 hours of operation or once every two years;
• the oil drain plug is located on the bottom side of the reservoir;
• hydraulic system oil volume: 70 L.
Hydraulic oil of suitable viscosity (46 mm²/s at 40°C).
The machine is factory filled with Hydrolubric VGS 46 (OLMA d.d.).
The hydraulic oil quality must correspond to the following standards:
STANDARD
Designation:
DIN
DIN 51 524/3 HVLP
ISO
ISO 6 743/4 HV
Denison
HF-2, HF-0
Vickers
I-286-S, M-2950-S
Cincinnati Milacron
P-68, P-69, P-70
7.8. REPLACING THE OIL FILTER
First replacement of the oil filter after 200 hours of operation, then after every 1000 hours of
operation.
The filter cartridge is not washable.
Reduced filter permeability can be observed on the filter gauge – if the gauge indicator is in the
red zone when the oil is heated to the operating temperature (if gauge indicator only sometimes
reaches the red zone, filter replacement is NOT necessary).
7.9. LUBRICATION OF THE MULTIPLICATION GEAR
The machine is factory filled with 1,2 L oil SAE 75 (Renolin CLP 100 DIN 51 517/13).
To prevent pollution dispose of the spent oil in a suitable manner!