background image

TAIYO ELECTRIC IND.CO.,LTD.

22

TAIYO ELECTRIC IND.CO.,LTD.

1

6

Key Operation

TEMP Display

3

2

4

5

Displays

alternately

How to Change the Code Number

Displays

alternately

Press the 

key.

Press and hold the

Example 

: When changing the 

code number from 123 to 234.

for over 3 seconds continuously.

Press the

keys so that the

present code number is displayed

Press the 

key.

Input the desired new code number

using the

keys.

Displays

alternately

Press the 

key.

Setting completed

key

Returns to the set 
temperature display.

Flashes 5 times

Summary of Contents for RX-802AS

Page 1: ...fety precautions in this manual and use the soldering station properly and only for what it is intended you will enjoy years of safe reliable service Thank you again for buying a goot soldering station WARNING Before using the soldering station read the Operation Manual Failure to follow the safety precautions and instructions in this manual could result in serious injury and property damage KEEP ...

Page 2: ...ury CAUTION Failure to obey a safety caution may result in a minor or moderate injury to yourself or to others Always follow the safety precautions to reduce the risk of electric shock fire or personal injury Safety Mark Definitions Following the WARNINGS and CAUTIONS in this manual will allow for the safe and proper use of the soldering station and should protect the operator from injury and oper...

Page 3: ...ore the Default Settings 24 5 Maintenance 26 5 1 How to Change the Tip 26 5 2 How to Change the Grip Rubber 27 5 3 Housing Cleaning 27 5 4 How to Use and Maintain a Lead Free Soldering Iron 27 6 Troubleshooting 28 7 Replacement Tips 29 8 Replacement Parts 30 9 Parameters 31 MODEL RX 802AS Voltage 110 120 130 220 230 240V AC Power Consumption 80W Soldering Iron Voltage Wattage 24V AC 72W Temperatur...

Page 4: ...tand ST 21 Operation Manual Please make sure that all the items listed below are included and that the soldering station control unit and soldering unit function properly If any items are missing or damaged please contact your goot distributor Please store the packaging for future shipment or repair 2 1 Unpacking TAIYO ELECTRIC IND CO LTD 4 2 Introduction ...

Page 5: ...o Rating Label Power Switch Tip Sold separately Slide Lever Grip Rubber Soldering Unit Connector Grip Adapter Output Terminal for Soldering Unit KEY LOCK RX 802 HEAT SLEEP TEMP C AS FRONT VIEW SIDE VIEW Operation Panel Cover Power Cord Rating Label Power Switch Tip Sold separately Slide Lever Grip Rubber Soldering Unit Connector Grip Adapter Output Terminal for Soldering Unit CAUTION 4 2 calibrati...

Page 6: ...thin the DIF range Turns off when the tip temperature is out of the DIF range Flashes when the tip temperature is out of the upper and lower temperature limits 5 KEY LOCK lamp Flashes while setting the Key Lock function Lights up when the unit is in Key Lock mode 6 KEY LOCK key Use to set the Key Lock function Use to lock and unlock the keypad 7 SETTING key This key is pressed when starting and co...

Page 7: ...lRemove the collected solder scrap regularly The angle of the front opening can be adjusted by loosening screws on the side Tip Stand ST 21C WARNING CAUTION lHigh temperatures Handle with care lTo avoid injury do not touch the metal part of the stand lTo prevent fire do not use the ST 21 near flammable substances lAlways place the stand on a stable worktable or other stable location to prevent inj...

Page 8: ... 4 WEAR PROPER APPAREL SAFETY GLASSES GLOVES AND MASK Do not wear loose clothing such as a necktie Tie up long hair Clothing or hair can burn on contact with the tip or surrounding heated parts 5 CONNECT TO THE SPECIFIED AC POWER SUPPLY The power voltage for this soldering station is indicated at the back of the control unit Never plug the soldering station into any other voltage 6 DO NOT ABUSE TH...

Page 9: ...t could be damaged Position the soldering iron stand on a flat work surface or bench 8 CONCERNING THE TIP After turning OFF the power switch allow the tip to cool naturally Never use any other method to cool it down For example Water should never be poured or sprinkled on the tip to cool it down 9 CONCERNING THE POWER CORD IF THE POWER CORD IS DAMAGED THEN THE SOLDERING STATION SHOULD BE RETURNED ...

Page 10: ...ature value Example If the set temperature is set at 200 C 392 F the sleep temperature must be 150 C 302 F or under 4 1 Changing the Set Temperature Displays flashes Refer to the Parameters table on for an explanation of the display messages Press the key Setting completed Press the Press and hold the key until the display shows key Example Changing the temperature from 250 C 482 F to 340 C 644 F ...

Page 11: ...ing the TIP number which is engraved on the tip The above tip number TIP NO may be changed without notice due to design changes etc Be sure to check the actual engraved tip number of your tip at the base Displays alternately 3 seconds continuously Press and hold the key for over 3 seconds continuously MODEL TIP SHAPE TIP NO RX 80HRT SB SB 3 RX 80HRT B B 1 RX 80HRT 2B 2B 1 RX 80HRT BM BM 1 RX 80HRT...

Page 12: ...he Type K thermocouple conduct heat which transfers away from the RX 802AS tip This results in the thermometer indicating a slightly lower temperature than the one in the RX 802AS display Key Operation TEMP Display 4 3 Calibration Function 3 Example Where the set temperature is 300 C 572 F tip thermometer value is 295 C 563 F and the calibra tion value to be input is 5 C 9 F Press the key once Pre...

Page 13: ...unction manually during the operation press and hold the key for one second continuously Active Sleep function While setting the Sleep function the Sleep lamp will flash The flashing of the Sleep lamp will increase 30 seconds before entering Sleep mode When the soldering station has entered Sleep mode the Sleep lamp will change from flashing to continuously lit and the display will alternate betwe...

Page 14: ...ll go out Set to 5 minutes before shipping Example Changing the sleep start time from 5 to 10 minutes Displays alternately Displays alternately Displays alternately Returns to the set temperature display Press and hold the key for over 3 seconds continuously Press the key three times Press the key until the display Setting completed Press and hold the key for over 3 seconds continuously changes fr...

Page 15: ...o 3 0 Displays alternately Displays alternately Displays alternately NOTE If the sleep sensitivity value DIF is set too high there is a possibility that the sleep function will be activated even during soldering If this happens reduce the sleep sensitivity value Sleep sensitivity value DIF can be set anywhere between 0 C 0 F and 20 0 C 36 0 F If the sleep sensitivity value DIF is set to low there ...

Page 16: ...wer ON Time Operation DIF DIF Sensitivity Shutdown start time 1 2 4 Key Operation TEMP Display 3 When SUT Shutdown start time value is set to 0 the shutdown function is OFF The display will alternate between Sdn and the temperature when the unit is in the shutdown mode The LED under the one digit on the TEMP window lights when the temperature Example Changing the Shutdown start time from 60 to 30 ...

Page 17: ...r over 3 seconds continuously Setting completed Returns to the set temperature display Press the Press the key 6 times to display At key Setting the soldering start time 1 RX 802AS star ts the soldering time count down when the tip temperature exceeds the set parameter 2 The alarm sounds after the soldering time preset is reached The display will also flash twice at this point 3 Lift the tip from ...

Page 18: ...imit Change the preset temperature by pressing the Lower Temperature Limit Lower Temperature Limit This function indicates to the operator with the sound of the alarm when the tip temperature goes past the set parameter The illustration on the right shows when the alarm will sound The diagonal lines represent outside the temperature parameters The alarm can be set from 3 to 100 C for the upper lim...

Page 19: ...nds Set to OFF for mute no sound Key Operation TEMP Display 4 8 Setting the Alarm Sound 3 Setting completed Press and hold the key for over 3 seconds continuously Press the key nine times Press the key to set to ON Press the key to set to OFF Press and hold the key for over 3 seconds continuously Displays alternately Displays alternately Displays alternately Displays alternately ...

Page 20: ...tion TEMP Display 3 Press the key ten times Press and hold the key for over 3 seconds continuously Displays alternately Press the key to change the format to F Fahrenheit F Press the key to change the format to C Fahrenheit C Returns to the set temperature display Setting completed Press and hold the key for over 3 seconds continuously Displays alternately Displays alternately Displays alternately...

Page 21: ...hree digit number from 001 to 999 l When the code number is set correctly the number will flash 5 times l If an incorrect code number is input the display will show NG and return to the initial display The Key Lock is set and released by the same procedure 4 10 Key Lock Function 1 3 Key Operation TEMP Display 2 Setting and Releasing the Code Number Returns to the set temperature display Displays a...

Page 22: ...the key Press and hold the Example When changing the code number from 123 to 234 for over 3 seconds continuously Press the keys so that the present code number is displayed Press the key Input the desired new code number using the keys Displays alternately Press the key Setting completed key Returns to the set temperature display Flashes 5 times ...

Page 23: ...place for future reference Resetting the Code Number 1 4 Key Operation TEMP Display 3 2 How to Reset the Code Number Press the key Press and hold the and the key simultaneously for over 3 seconds Press the keys so that the present code number is displayed Press the key Resetting completed Displays alternately Displays alternately NOTE The number 471 is the unique number to reset This can be used e...

Page 24: ...fault settings set before the unit was shipped The key lock function is also unlocked using this procedure This can allow a third party to alter the settings on the unit Please keep this manual with authorized personnel only and in a safe place for future reference Though the key lock can be released by doing the procedure shown above the code number cannot be reset To reset the code number follow...

Page 25: ...TAIYO ELECTRIC IND CO LTD 25 ...

Page 26: ...g unit automatically goes off as soon as the lever is slid forward to remove the tip 3 Plug the new tip into the end of the soldering unit making sure that the cut part of the tip is aligned with the cut part of the soldering unit Push the tip into the handpiece as far as it will go The tip will not heat up until any key on the control unit keypad is pressed 5 1 How to Change the Tip NOTE When cha...

Page 27: ...starts as soon as the tool is plugged in and begins to heat When opera tion is completed tin the solder coated area of the tip with solder and unplug it This protects the tip from oxidation when it starts heating up the next time it is in use A lead free soldering iron is more susceptible to oxidation and it is more difficult to wet the tip with solder Flux within the solder adheres to the tip car...

Page 28: ...he items below before sending for service or repair The power does not go ON Check that the power cord is plugged in Check that the fuse is not blown The soldering iron tip does not heat up Check that the heater is not damaged Error message Cause Countermeasure The sensor or cord is damaged Replace the tip or soldering unit This message is also displayed when changing the tip but this is not an er...

Page 29: ... 45 3 10 5 φ 4 7 0 5 9 60 1 φ 4 7 10 3 60 φ2 45 φ 4 7 11 5 5 RX 80HRT 2CD RX 80HRT 3C RX 80HRT 3CD RX 80HRT 4C 45 φ2 11 5 1 2 2 φ3 45 φ 4 7 11 5 5 5 φ3 2 3 45 11 5 φ4 φ 4 7 12 6 45 RX 80HRT 4 7C RX 80HRT 0 8D RX 80HRT 1 2D RX 80HRT 1 6D φ4 7 45 8 5 5 φ 4 7 10 3 0 4 φ 0 8 φ 4 7 10 3 0 4 φ1 2 φ 4 7 10 5 0 5 φ1 6 3 2 RX 80HRT 2 4D RX 80HRT 3 2D RX 80HRT 5 4D RX 80HRT 3K φ 4 7 10 6 0 5 4 5 φ2 4 φ 4 7 ...

Page 30: ...SERIES 3 Soldering Iron Stand Sponge ST 53SP Replacement sponge for ST 21 4 Soldering Iron Stand Cleaner ST 40BW Replacement Brass shaving for ST 21 2pcs set Four different colors available Handy to differentiate stations being used for different tasks in the same workspace Grip Rubber Selection Grip rubber gray RX 80RB Anti Static Grip rubber black RX 80RB BK Grip rubber orange RX 80RB OR Grip ru...

Page 31: ...ture Calibration cAL C F 50 50 90 90 0 0 Sleep Set Temp SSt C F 0 Pt 50 0 Pt 90 200 392 Sleep Timer ct Minute 0 00 999 5 Sleep Sensitivity diF C F 0 20 0 0 36 0 2 0 3 6 Shutdown Start time SUt Minute 0 999 60 Alarm At sec 0 3 30 Upper Limit H C F 3 100 5 180 50 90 Lower Limit L C F 3 100 5 180 50 90 Buzzer Sound ON OFF ON Temperature Scale c F c TAIYO ELECTRIC IND CO LTD 31 ...

Page 32: ...MENT AND ACCESSORIES TAIYO ELECTRIC IND CO LTD Customer service Contact your nearest distributor goot is registered trade mark of TAIYO ELECTRIC IND CO LTD Printed in Japan JULY 2014 A1220MY00 AOB HomePage www goot co jp E mail info goot co jp ...