The sleep start timer (CT) function automati-
cally lowers the temperature of the tip after a
preset period of inactivity. This function reduc-
es power consumption and helps extend sol-
dering tip life. This sleep function can be used
with the shutdown function (see 4-5) together.
4-4 Sleep Function
CT
SST
So
ld
er
in
g
tip
te
m
pe
ra
tu
re
Set temperature
Sleep start
DIF
Operation
DIF
(Sensitivity)
Power ON
Time
(Sleep start time)
(Sleep setting temp.)
1
2
4
Unit: °C
Key Operation
TEMP Display
Set to 200°C (392°F) before shipping.
Example
: Changing the sleep temperature
from 200°C (392°F) to 150°C (302°F).
3
Displays
alternately
Displays
alternately
Displays
alternately
Returns to the set
temperature display.
Press and hold the
key for over
3 seconds continuously.
Press the
key twice.
Press the
key, until the display
Setting completed
Press and hold the
key for over
3 seconds continuously.
changes to
150
.
To use Sleep function manually during the operation, press and hold the
key for one second
continuously. (Active Sleep function) While setting the Sleep function, the Sleep lamp will flash.
The flashing of the Sleep lamp will increase 30 seconds before entering Sleep mode.
When the soldering station has entered Sleep mode, the Sleep lamp will change from flashing to
continuously lit, and the display will alternate between “SLP” and the temperature.
When the power is turned ON, no work is started and nothing is pressed on the keypad, the soldering
station will automatically enter Sleep mode either 10 minutes after the power has been turned ON or
in twice the set sleep time (CT), whichever time is longer. However, if soldering is started or keys are
pressed on the control panel, the soldering station will automatically revert to the set sleep start time.
Sleep mode can be exited by rubbing the tip on the moist
sponge. But when Sleep temperature (SST) is 99°C
or below, Sleep mode cannot be exited because the
temperature changing range is too small. To exit Sleep
mode, press any key on the control panel and the tip will
return to the set temperature.