Environmental Conditions
2.3.1
Operating Temperature Range
The operating temperature range of the equipment is –22°F to +140°F
(–30°C to +60°C) ambient temperature. Ambient temperature is defined as
the temperature of the air at the intake to the cooling fans.
2.3.2
Humidity
The humidity should not exceed 95% relative humidity through the
specified operating temperature range.
2.3.3
Dust and Dirt
For uncontrolled environments, the level of airborne particulates must not
exceed 100µg/m
3
.
2.4
Regulatory Information
2.4.1
Distress Frequencies
The 406 to 406.1MHz frequency range is reserved worldwide for use by
Distress Beacons. Do
not
program transmitters to operate in this frequency
range.
2.4.2
Compliance Standards
This equipment has been tested and approved to various national and
international standards. Refer to the latest issue of the Specifications
Manual for a complete list of these standards.
2.4.3
Unauthorized Modifications
Any modifications you make to this equipment which are not authorized by
Tait may invalidate your compliance authority’s approval to operate the
equipment.
The manufacturer is not responsible for any radio or TV interference
caused by unauthorized modifications to this equipment. Such
modifications could void the user’s authority to operate the equipment.
Summary of Contents for TB7300
Page 1: ...TB7300 Base Station Installation and Operation Manual MBD 00001 04 Issue 4 November 2016...
Page 2: ...2 TB7300 Installation and Operation Manual Tait Limited November 2016...
Page 6: ...TB7300 Installation and Operation Manual 6 Tait Limited November 2016...
Page 10: ...10 Preface TB7300 Installation and Operation Manual Tait Limited November 2016...
Page 28: ...28 Operation TB7300 Installation and Operation Manual Tait Limited November 2016...
Page 68: ...68 Installation TB7300 Installation and Operation Manual Tait Limited November 2016...
Page 70: ...70 Maintenance TB7300 Installation and Operation Manual Tait Limited November 2016...
Page 72: ...72 Troubleshooting TB7300 Installation and Operation Manual Tait Limited November 2016...
Page 84: ...84 Glossary TB7300 Installation and Operation Manual Tait Limited November 2016...