3-6
INSTALLATIONS
3.3.2 Using different clock source
Changing CO Site’s clock source of DT-2000F to Network clock or internal clocks.
The following steps can easily complete quick installation. Step 1. When trying to use
different clock source for HDSL transmission, the different configuration that needs to
be changed is on "SET E1 Clock" item only. The operation example of menu tree are
listed as below:
v
Clock Source
à
from DT-2000F Internal
1. HDSL CONFIG
à
SYSTEM TYPE
à
E1-C
2. HDSL CONFIG
à
E1 FRAME FORMAT
à
UNFRAME
3. HDSL CONFIG
à
SET E1 CLOCK
à
INTERNAL
v
Clock Source
à
follow CO site data equipment
1. HDSL CONFIG
à
SYSTEM TYPE
à
E1-C
2. HDSL CONFIG
à
E1 FRAME FORMAT
à
UNFRAME
3. HDSL CONFIG
à
SET E1 CLOCK
à
NETWORK
After went through this quick installation example, user may easily transmit the Full-E1
2.048Mbps data pass through DT-2000F HDSL pair. For more detail items and
function descriptions, please refer to chapter 4.