background image

 CNC-110A Series  C-03/C-13 User's manual

 

5

 

 

 

έᚊ࿪ཝҋજ̼ѣࢨ̳Φ

 

 

TAILY AUTOMATION CO.,LTD.

 

6. CONFIGURATION 

SETTING 

CNC-110AS is a multi-purpose design, to meet various requirements; additional settings are 

configured to provide flexibility for additional applications. 

In the READY mode, pressing the following keys combination as

 (6.1. ~6.9.)

 all the parameters 

can be changed. 

6.1. Zero point 

Select the winding spindle shaft is need or not having a zero point.   

With zero point 

. (Use with zeroing disc. See section 10.1.) 

Without zero point 

6.2. Braking mode 

The SINGLE MODE is to brake until the end of each winding step

.

   

The DOUBLE MODE is to brake a short period when the turns number match the SLOW STOP 

TURNS, then winding to the end by LOW speed, and brake another time to finish the step

.

 

Single mode 

.                Double mode

6.3. Counting mode 

The RELATIVE MODE is to reset the TURNS COUNTER to zero without any consideration 

before start winding.   

The ABSOLUTE MODE is to reset the integer portion of TURNS COUNTER to zero, but keep 

the decimal portion unchanged. 

Relative mode 

.     Absolute mode

6.4. Starting mode 

ON-OFF mode means when press the foot switch, the motor start winding, and when you 

release the foot switch, the motor stop winding immediately.   

TRIGGER mode means when press the foot switch, the motor start winding, and if you want to 

pause the motor, you have to release the foot switch then press it again.   

The

key on the front panel always as the Double start mode.   

Single start mode 

.    Double start mode

6.5. Counting unit 

You can choose 0.1 or 1 turns as your count unit. After you choose the unit, the TURNS 

COUNTER, and the winding parameters setting will use it as their basic unit. 

Unit = 1 

.          Unit = 0.1

6.6. Brake holding times 

In READY mode, press

keys, to set the holding times for brake. 

[Setting range 0.1~9.9 sec], if you set the braking time as 0.0sec, the controller will used the 

default time 0.3sec. 

Summary of Contents for CNC-110A Series

Page 1: ...INTRODUCTION 2 2 MAIN FEATURES 2 3 FRONT PANEL DESCRIPTION 3 4 MEMORY GROUP SELECTION 4 5 WINDING PARAMETERS SETTING 4 6 CONFIGURATION SETTING 5 7 WINDING EXECUTION 7 8 ADJUSTMENT 8 9 FUNCTION TABLE 9...

Page 2: ...also offers CNC 110AE External connection model depending on whether a close loop driver is provided for various applications CNC 110AS With 0 5HP DC motor driver CNC 110AE With winding spindle shaft...

Page 3: ...SLOW STOP TURNS Saving the data to the memory and finish the setting procedure To shows all the winding parameter from first to last STEP To change the display mode To start winding or to pause windi...

Page 4: ...wound Setting range 0 99999 turns or 0 0 9999 9 turns Setting SLOW STOP TURNS Number of SLOW STOP TURNS Setting range 0 79 9 turns Select winding direction Saving the data to the memory and finish the...

Page 5: ...the TURNS COUNTER to zero without any consideration before start winding The ABSOLUTE MODE is to reset the integer portion of TURNS COUNTER to zero but keep the decimal portion unchanged Relative mod...

Page 6: ...t the SLOW STOP TURNS Setting range 0 1 9 9 turns If you do not need this function set it in 0 0 to start winding in high speed 6 8 Brake status Select brake status during motor stop Brake off Brake o...

Page 7: ...ADY mode External control signal RES REV at C 13 edition represents REVERSE During PAUSE mode contact it with COM then restart winding process the winding spindle will run by opposite direction in LOW...

Page 8: ...ee Figure 1 2 Rotate CL to the left end L and rotate MAX to the right end H 3 Rotate H S and L S potentiometer on back panel to the right end H Then press key to start winding in high speed 4 Rotate C...

Page 9: ...see Figure 1 or Figure 3 There are two control mode can be select 1 1C The CN5 pin2 represent winding RUN output The CN5 pin3 represents winding direction DIR output 2 2C The CN5 pin2 represent clockw...

Page 10: ...embly as below ZEROING DISC COUNTING SENSORS OPTION COUNTING DISC CNTB 03B 03C 1 0 MAX WINDING SPINDLE 6 0 MIN ZEROING SENSOR Unit mm The zeroing disc is not served with the controller If you need a z...

Page 11: ...3 4 5 6 H S L S 1 2 3 1 2 3 EXTERNAL SPEED ADJUST INTERNAL SPEED ADJUST OPTION FOOT SW TURNS COUNTER CNTB 03B CNTB 03C 10 3 External wiring diagram for CNC 110AE CN5 CN1 CN6 CN3 1 2 110AS 002E sch CN...

Page 12: ...TF 015B 110B DVR 1 2 3 4 CN2 Y Y R R 20V 9V 0V 0V 0V 110V 220V 240V 8V 0V 8V BK W BL BR Y R Y 1 2 3 1 2 3 VR 10K VR 10K L S H S 10 5 Internal wiring diagram for CNC 110AE 110AS 005E sch 1 2 3 4 CN5 1...

Page 13: ...rollers are properly grounded 5 Make sure that the leads and connectors are connected correctly 6 Normally operate under 5 50 environment over 40 should perform under good ventilation avoid heating 11...

Page 14: ...eplace 110A CPU 3 Fuse failure a Replace fuse b Replace 110B DVR c Replace transformer TF 015B 4 Cannot edit parameters a Replace 110AS KEY BOARD b Replace 110A CPU 5 Winding spindles motor cannot wor...

Page 15: ...MENSIONS 20 0 150 0 20 0 30 0 85 0 31 0 90 0 10 0 CNC 110AS CNC 110AE 1 5 6 0 7 0 13 0 9 0 12 0 3 5 14 5 15 0 14 5 51 0 3 2 x 2 10 0 1 0 71 71 3 1 x 4 R10 0 R 1 3 0 R 2 8 0 Counting Sensor CNTB 03B Co...