11.1.Requirement and Safety precautions 

1. The controller should be operated in an environment that is protected from moisture, corrosive 

gases, or liquid, and free from airborne dust, metallic particles, and magnetic noise. 

2. Make sure that the power source supplies the correct voltage and is capable of supplying the 

required current to the controllers.

 

3. Do not connect or disconnect wires and connectors while power is applied to the controller. 

4. Make sure the machine and controllers are properly grounded.

 

5. Make sure that the leads and connectors are connected correctly. 

6. Normally operate under 5

 ~ 50

 environment, over 40

 should perform under good 

ventilation, avoid heating. 

11.2.Periodically maintain 

The following parts must be maintained or changed periodically as list below. If any part is found 

faulty, it must be changed immediately even when it has not yet reached the end of its life, which 

depends on the operating method and environmental condition. For parts replacement, please 

contact your sales representative. 

NO 

Part name 

Life guideline 

 1 

Winding spindles Turns counter 

CNTB-03B/03C

   

2 years 

 2 

RELAY

 (

RY-BLY

board, it used to switching the winding 

direction) 

100,000 times 

Carbon

 BRUSH

 in the DC motor 

1 years 

Summary of Contents for CNC-110A Series

Page 1: ...INTRODUCTION 2 2 MAIN FEATURES 2 3 FRONT PANEL DESCRIPTION 3 4 MEMORY GROUP SELECTION 4 5 WINDING PARAMETERS SETTING 4 6 CONFIGURATION SETTING 5 7 WINDING EXECUTION 7 8 ADJUSTMENT 8 9 FUNCTION TABLE 9...

Page 2: ...also offers CNC 110AE External connection model depending on whether a close loop driver is provided for various applications CNC 110AS With 0 5HP DC motor driver CNC 110AE With winding spindle shaft...

Page 3: ...SLOW STOP TURNS Saving the data to the memory and finish the setting procedure To shows all the winding parameter from first to last STEP To change the display mode To start winding or to pause windi...

Page 4: ...wound Setting range 0 99999 turns or 0 0 9999 9 turns Setting SLOW STOP TURNS Number of SLOW STOP TURNS Setting range 0 79 9 turns Select winding direction Saving the data to the memory and finish the...

Page 5: ...the TURNS COUNTER to zero without any consideration before start winding The ABSOLUTE MODE is to reset the integer portion of TURNS COUNTER to zero but keep the decimal portion unchanged Relative mod...

Page 6: ...t the SLOW STOP TURNS Setting range 0 1 9 9 turns If you do not need this function set it in 0 0 to start winding in high speed 6 8 Brake status Select brake status during motor stop Brake off Brake o...

Page 7: ...ADY mode External control signal RES REV at C 13 edition represents REVERSE During PAUSE mode contact it with COM then restart winding process the winding spindle will run by opposite direction in LOW...

Page 8: ...ee Figure 1 2 Rotate CL to the left end L and rotate MAX to the right end H 3 Rotate H S and L S potentiometer on back panel to the right end H Then press key to start winding in high speed 4 Rotate C...

Page 9: ...see Figure 1 or Figure 3 There are two control mode can be select 1 1C The CN5 pin2 represent winding RUN output The CN5 pin3 represents winding direction DIR output 2 2C The CN5 pin2 represent clockw...

Page 10: ...embly as below ZEROING DISC COUNTING SENSORS OPTION COUNTING DISC CNTB 03B 03C 1 0 MAX WINDING SPINDLE 6 0 MIN ZEROING SENSOR Unit mm The zeroing disc is not served with the controller If you need a z...

Page 11: ...3 4 5 6 H S L S 1 2 3 1 2 3 EXTERNAL SPEED ADJUST INTERNAL SPEED ADJUST OPTION FOOT SW TURNS COUNTER CNTB 03B CNTB 03C 10 3 External wiring diagram for CNC 110AE CN5 CN1 CN6 CN3 1 2 110AS 002E sch CN...

Page 12: ...TF 015B 110B DVR 1 2 3 4 CN2 Y Y R R 20V 9V 0V 0V 0V 110V 220V 240V 8V 0V 8V BK W BL BR Y R Y 1 2 3 1 2 3 VR 10K VR 10K L S H S 10 5 Internal wiring diagram for CNC 110AE 110AS 005E sch 1 2 3 4 CN5 1...

Page 13: ...rollers are properly grounded 5 Make sure that the leads and connectors are connected correctly 6 Normally operate under 5 50 environment over 40 should perform under good ventilation avoid heating 11...

Page 14: ...eplace 110A CPU 3 Fuse failure a Replace fuse b Replace 110B DVR c Replace transformer TF 015B 4 Cannot edit parameters a Replace 110AS KEY BOARD b Replace 110A CPU 5 Winding spindles motor cannot wor...

Page 15: ...MENSIONS 20 0 150 0 20 0 30 0 85 0 31 0 90 0 10 0 CNC 110AS CNC 110AE 1 5 6 0 7 0 13 0 9 0 12 0 3 5 14 5 15 0 14 5 51 0 3 2 x 2 10 0 1 0 71 71 3 1 x 4 R10 0 R 1 3 0 R 2 8 0 Counting Sensor CNTB 03B Co...

Reviews: