CNC-110A Series C-03/C-13 User's manual
8
έᚊཝҋજ̼ѣࢨ̳Φ
TAILY AUTOMATION CO.,LTD.
8. ADJUSTMENT
CL
I R
110B-DVRID:XXXXXX
TAILY
AUTO
0
10
10
A
DC Amperes meter
10A
M
110AS-006E.sch
DC Motor
MAX
110V
220V
110A-EXDID:XXXXXX
TAILY
AUTO
JP1
RUN/DIR
CW/CCW
1C
2C
110V
220V
CN4
220V
110V
110B-DVR
WINDING SPINDLE DC MOTOR DRIVER BOARD
CNC-110AS STANDART MODEL
L
H
L
H
L
H
CL
IR
MAX
110A-EXD
WINDING SPINDLE MOTOR CONTROL BOARD
CNC-110EXD EXTERNAL CONNECTION MODEL
WINDING SPINDLE SHAFT DRIVER
CONTROL MODE SELECT
8.1. Standard model (CNC-110AS)
CL
:
Maximum output current limit.
1. Locking the winding spindle shaft, to make it cannot move;
connect a DC Amperes meter
between terminal and DC motor. (See Figure-1).
2. Rotate CL to the left end [L], and rotate MAX to the right end [H].
3. Rotate H.S. and L.S. potentiometer on back panel, to the right end [H].
Then press
key to start winding in high speed.
4. Rotate CL in clockwise to set limited current,
show on Amperes meter.
(Limited current = 2A when using DC 180 volt motor).
(Limited current = 4A when using DC 90 volt motor).
Then press
key to stop winding. Release the
winding spindle shaft.
*
The CL have been set by factory before delivery. Only adjust it when change DC motor
or replace 210-DVR driver board.
*
IR
:
Torque compensation.
1. Rotate H.S. potentiometer on back panel, to the left end [L],
and press
key to change the
TURNS DISPLAY shows winding speed (RPM).
Then press
key to start winding in low speed.
2. Rotate IR to make the winding in same speed (RPM)
during the winding spindle shaft in
full-load and unload.
Then press
key to stop winding.