![Tailift TPR720A Operation Manual Download Page 20](http://html1.mh-extra.com/html/tailift/tpr720a/tpr720a_operation-manual_3265689020.webp)
3-5
3.4.2 For TPR-1100
Motor Part Name
Rated Power Capacity
Maximum Initiate Power
Main Motor
2.25kw
6.3kw
Elevating Motor
0.75kw
2.1kw
Coolant Pump Motor
0.1kw
0.28kw
Total Rated Power Capacity:
(1.5kw+0.75kw+0.1kw)=3.1kw………………….. (1)
Maximum Total Initiate Power Capacity:
(4.2kw+2.1kw+0.28kw)=8.68kw…………………..(2)
Transformer Rated Output Power Capacity for Control Circuits
Model
Item
100VA
Input
AC400V
±
±±
±
10% 1
∅
∅
∅
∅
Power Supply
Output
AC240V
±
±±
±
10% 1
∅
∅
∅
∅
Ambient Temperature
0°C To 55°C
S=KVA
P=KW
Pf
×
××
×
n = 0.75 (Correction Factors)
S=
KW
Pf
×
××
×
n(0.75)
P=
3.1Kw
0.75
=4.133KVA………………………(1)
P=
8.68Kw
0.75
=11.573KVA……………………(2)
Power Equipment Capacity=
4.11.573KVA
2
=7.853KVA