• Is the power cord plug fully pushed into the wall outlet?

• Is the sake warming temperature set at OFF?

After-Sales Service

Before Calling a Service Person 

Before calling a service person, carefully read this manual and check the following.

Trouble

Sake is not warmed.

Sake is dispensed, but too little.

• Use the manual button to operate until sake comes out smoothly.

This can often occur when cubic container are replaced.

It is caused because air in the pipe is pushed out.

• Check whether the nozzle area is contaminated.

If contaminated, neatly clean the electrode part (metallic rod) in the

nozzle by the use of a tooth brush.

Temperature does not rise.

• Is the water bath tank full with water at the level of water level indicator?

Feed water or warm water through the water tank inlet.

• Considered to be a problem in the temperature sensor.

In this case, the replacement of sensor is required.

Temperature rises too high.

• Is the sake warming temperature set at a favorite level?

• Considered to be a problem in the temperature sensor.

In this case, the replacement of sensor is required.

Check

Disassembly Prohibited

Very special techniques are required for repairing.

Users are absolutely prohibited to carry out overhaul and fixing.

*

The specifications and part of the appearance are subject to change for improvement without notice.

TSK-130B

Heating method

Electrical (indirect heating)

Rating

110-120V AC, 50/60 Hz

Sake feeder

Cubic container, 5 to 18 liters

Power consumption

1kW

Water bath tank, Approx. 4.7 liters

Weight

Approx. 9.3kg

Dimensions

W 250 x D 375 x H 515 mm

Power cord

Rubber sheathed cord,

2m in effective length

Accessories

Bottle holder funnel, 1 pc.

Silicone tubing, 1 pc.

Stopcock, 1 pc.

Specifications

TAIJI & CO., LTD.

8-2, Okawa-cho, Kawasaki-ku, Kawasaki--shi, Kanagawa-ken 210-0858, Japan

Telephone:  81-44-329-6338     Fax:  81-44-329-5860

URL http://www.taiji.co.jp/e

Email: [email protected]

Printed in Japan

                 (2310G)

Summary of Contents for TSK-130B

Page 1: ...TSK 130B Operating Instructions SakeWarmerDispenser...

Page 2: ...ng the appliance The serial number of this product may be found on the bottom of the unit You should note the serial number of this unit in the space provided and retain this book as a per tion in the...

Page 3: ...to use your new product in a manner which does not conform to the instructions given herein Introduction Use This product is a sake warmer exclusively for indoor use It is intended to make Japanese s...

Page 4: ...Hot water comes out of the nozzle while the inside is cleaned Pay attention to a possible accident of scalding etc 5 Clean the sake warmer heat exchanger pipe This product is already cleaned inside be...

Page 5: ...dicate the present temperature 5 When the preset temperature is attained all the lamp up to the preset temperature are lit As a guideline when the HOT temperature is preset this temperature is attaine...

Page 6: ...is positioned slantwise 7 Drain the remaining sake from the dispenser 1 Turn the knob of the stopcock to the left and adjust it to the CLOSE position Fig 20 If this operation is omitted sake in the C...

Page 7: ...osition Push the nozzle straight down or press the manual dispensing switch 4 Hot water comes out of the nozzle and the pipe inside is cleaned 5 After cleaning remove the cubic container for cleaning...

Page 8: ...e replacement of sensor is required Temperature rises too high Is the sake warming temperature set at a favorite level Considered to be a problem in the temperature sensor In this case the replacement...

Reviews: