46
Chapter 5. Charging Case and Storage case
5.1 Charging case
5.1.1 Overview
The charging Case can charge up to 60 receivers at a
time. It uses universal power supply with automatic
voltage matching. There is a charging indicator on the
receiver. The charging circuit will check if the battery
pack is present and control the charging process.
Figure 5.1 HCS-5100CHG/60 Charging Case
Figure 5.1:
1.
Power switch
Just switches on/off power for charging lattice.
Does not switch power input
2.
Power input
3.
Charging lattice
5.1.2 Charging procedure
1. Connect power cord;
2. Switch
on;
3. Insert
receiver;
4. Receiver charging indicator lights up.
LED Status
Charging Status
On Charging
completed
Blinking Charging
Off
Charger power off or receiver not
inserted properly.
Note:
The Charging Case is only used to charge
HCS-5100R with battery pack
HCS-5100BAT-16. Please do not charge other
receiver types with HCS-5100CHG/60 or
charge HCS-5100R with other charging unit.
Note:
Pull out the earphone before charging the
receiver.
Switch on the charger before inserting the
receiver. Inserting and removing the receiver
when the charger is powered on will not
damage the receiver.
To maintain the service life of the Ni-MH battery,
please charge it for 24 hours before first service
(until the charging indicator keeps lighting).
The charger supplies fast charge during the first
10 minutes after inserting the receiver. So
please do not frequently insert and remove the
receiver to protect the battery pack.
Continuously charging will not damage the
receiver or the battery pack.
Please charge up the receiver in a temperature
between 0 and 45 centigrade, or else will
tamper with the life of receiver.
It will result in low battery and may damage the
battery pack if the battery pack is not used for a
long time. Please fully charge the battery every
three months.
Please check the battery pack regularly every 3
years whether the battery pack is leaking or not.
If any leakage or corrosion is detected, please
replace the battery pack. Please use
HCS-5100BAT-16 only. The battery pack should
be replaced at least every 5 years.