SmaFinger
PROMAG
REV.A
14
Test SmaFinger Reader after configuration
After SmaFinger configuration is completed you may use Mifare Reader Utility "Test" function to test the
SmaFinger to see if the configuration is done correctly.
1.
After the configuration on the Mifare Reader Utility software is made, you should click [Update Reader] to
download the current configuration to the SmaFinger Reader.
2.
After SmaFinger configuration is completed, you may click [Test] to test SmaFinger Reader.
3.
Get an issued mifare
®
card to put on SmaFinger reader to be read and see the output data on the window
of "SmaFinger Output Test".
Wiegand 34 bits output data with standard bit sequence, example as below: (If "Bit Sequence" is standard,
Reverse will detect a wrong with parity error.)
Remark:
1.
Using Reader-Kit to test Wiegand (or TK2) signal, this test may be failed if the processor of computer is
too slow.
2.
Using Reader-Kit to test Wiegand (or TK2) signal, you have to connect to the physical Comm. Port.