![TAGnology SmaFinger User Manual Download Page 4](http://html.mh-extra.com/html/tagnology/smafinger/smafinger_user-manual_813677004.webp)
SmaFinger
PROMAG
REV.A
4
User-Data Format
SmaFinger will send out the data following the format as below, the user data length defined by the Data-Info.
At wiegand output format, the data output length is fixed (defined by Number Of Bits), so the user data would
be cut if longer than Number of Bits, or the user data would be appended with zero "0" if shorter than Number
of Bits.
Byte 0
Byte 15
Block 0
Data-Info
Block 1
Block 2
USER DATA (Max 128 Bytes)
Application
Sector #
Block 3
Data-Info
bit7
bit6
bit5
bit0
Data Type (11b)
Data Length
Data Type is fixed with 11b which meets "any other data" type of "Card Holder information" as MAD standard.
And data length is including the data with ending zero "0", so the number of data byte sent by SmaFinger is
equal to data length with one less for RS232 output.
Example: Data Length is 16, SmaFinger only send out 15 bytes for RS232 output.