TagMaster AB
HW Installation Guide
MECHANICAL INSTALLATION
Manual issue 01
16
9.2.2
Connecting Cable recommendation
Core:
Conductor: 0.6mm² 19/0.2mm tinned copper
Insulation: Conforms to RSE/STD/024 – Part 6 Type IV
Diameter: 1.40mm ± 0.05mm
Pair
:
2) of the above Cores twinned together
Cable Assembly:
3) of the above Pairs (Items 1-3) cabled together
Binder:
Wrapped with polyester tape
Drain wire: 0.6mm² 19/0.2mm tinned copper
Screen:
0.127mm tinned copper braid, 84% minimum coverage
Sheath:
Black irradiation cross-linked ZX elastomer
1.15mm nominal radial thickness
Diameter:
8.05mm ± 0.5mm
Colour Code:
Pair Cores Blue, Brown and number printed 1 to 3
Maximal Cable Length:
20
m
CAUTION The cable is recommended to fulfil theses requirements. The reader might
not work properly if these recommendations are neglected.