8.

 

Camera relay strike 

 Set the camera relay strike time (play time, default 30 sec). 

Example:

 change the camera uptime to 40 seconds. 

Enter remote programming mode, Enter cell number 14, followed by the new value 
you want to set 40(two digits), and then press Hash (#) key to approve. 

 

B.

 

Connecting a second lock Instead of Camera

 

To connect second locks instead of the camera follow the next steps 

1.

 

Set the Camera relay strike time

 (Set in the cell 14, value 00) 

2.

 

Set the tone open number

 (watch page # 6, chapter 9 )

.

 

Set the different opening keys from the extension. 

3.

 

Connect the lock's wires between the CAMRA terminals. The opening modes will 
"Normally Open" only. 
The Opening and Delay times set to the first lock applicable to the second.  

Caution: wrong connection might cause irreversible damage to the unit 

 

9.

 

Tone Open Number

 – 

These steps will program the tone open number – the 

key you will press from the PBX telephone to grant entry for the first relay, and the 
second if exist (for second lock - see page # 8, part 8, and section 7.2). 

One lock mode 

 Enter the tone open number twice (77) 

Example

change the tone open number to 7.

 

 

Enter remote programming mode, Enter cell number 13, set the new tone open 
number 77(same two digits), and then press Hash (#) key to approve. 

 

Example

change the first tone open number to 7 and the second to 8. 

Enter remote programming mode, Enter cell number 13, set the new tone open 
number want 78(two digits – first digit is for first lock, second digit for the second 
lock), and then press Hash (#) key to approve.

 

 

 
 

10.

 

Pushbutton delay 

This is a time that passing after pushbutton pressing to actually lock activation (in 
standard situation no need to change). The data located in memory cell 05.  
Usually using when pushbutton located far away from the door 
Example: Set delay time 3seconds   

Exit  Programming mode

 

Approval

 

New value

 

Cell number

 

programming

 

Programming code

 

##(Hash)

 

#

 

45

 

11

 

##

 

Call  Doorphone

 

Exit  Programming mode

 

Approval

 

New key

 

Cell number

 

programming

 

Programming code

 

##(Hash)

 

#

 

77

 

11

 

##

 

Call  Doorphone

 

Exit  Programming mode

 

Approval

 

New keys

 

Cell number

 

programming

 

Programming code

 

##(Hash)

 

#

 

78

 

11

 

##

 

Call  Doorphone

 

Exit  Programming mode

 

Approval

 

New value

 

Cell number

 

programming

 

Programming code

 

##(Hash)

 

#

 

03

 

50

 

##

 

Call  Doorphone

 

Summary of Contents for KX-T927-MTL

Page 1: ...1 33311 ENG Doorphone Door Access Communicator Instruction Manual KX T927 Please read this manual carefully before using the product KX T927 MTL KX T927 MTL Rfid ...

Page 2: ...eiving a call from the door panel can speak with the visitor and open the door from his telephone extension by pressing a particular key Open the door from the inside is possible by pressing a bypass pushbutton 3 Specifications Operating voltage 12V Voltage Transformer rates at least 1000mA Running electric lock or magnetic lock Normally Open or Normally Close Panel Dimension o Surface Mount o Flu...

Page 3: ...nd prepare the wires infrastructure 1 Two wires from the power supply 2 Two wires to the lock 3 Two wires from a telephone exchange free extension 4 2 wires from optional bypass pushbutton if installed Assemble the wires through the hole on the back box of Tador Doorphone Mark the four drill points of the back box on the wall Drill and install the back box to the wall Make sure the AC adapter is u...

Page 4: ...on number 347 to set for speed dial and then press Hash key to approve 2 Hash Dial for IP PBX only on IP PBX Hash is required at the end of the number Example Set the bell key to fast dial to extension 347 Enter remote programming mode Enter the cell number 50 followed by the extension number 347 then press 2 and then Hash key to approve 3 Adding two seconds pause on dial Example When pressing the...

Page 5: ...er cell number 11 followed by the new time that you want to set 90 two digits and then press Hash key to approve 7 Number of Rings to Answer This programming section sets the number of rings that the Tador Doorphone will allow to pass through the system before it picks up the call Cell number 12 default one ring Example Change the number of ring to answer to 3 rings Enter remote programming mode E...

Page 6: ...ection 7 2 One lock mode Enter the tone open number twice 77 Example change the tone open number to 7 Enter remote programming mode Enter cell number 13 set the new tone open number 77 same two digits and then press Hash key to approve Example change the first tone open number to 7 and the second to 8 Enter remote programming mode Enter cell number 13 set the new tone open number want 78 two digit...

Page 7: ... case the device is virgin never programmed RFID cards the first card will be store in memory sell 001 second in 002 and so on In case device already been programmed with RFID cards in past the first card will be store in first unfilled sell Example you have programmed 10 RFID card in past and want to add more cards now The first card you add now will be store in sell 011 second in 012 and so on E...

Page 8: ...1 Example Replace RFID card that stored in memory cell 009 12 RFID card resetting initialization a Enter the program mode by b Press 97 c Press 5555 to reset all programmed RFID long special tone will heard d Press hash key to exit program mode 13 Door opening delay This is a time that passing after coupling RFID card to actually lock activation in standard situation no need to change Usually usin...

Page 9: ...s are located below connector DEF 4 Connect the power supply to Tador Doorphone 5 Wait about 3 seconds until the tune stops indicating completion of the process 6 Remove the jumper from drills PRG 7 Reinstall jumper on connector DEF between the central pin and the pin below it D Speaker volume adjustments Tador Doorphone comes from the manufacture with the microphone volume optimally adjusted Some...

Page 10: ...Telephone extation Electric lock RELAY SPK Volume SPK CAM Button Connector Bypass pushbutton N O N C JM1 DEF PRG For programming and restore move the jumper up For restoring device add jumper on PRG Remove the jumper after restore completion Call buton Remote ...

Page 11: ...11 ...

Page 12: ...12 Thank you for choosing our products www Tador com All rights reserved to Tador Technologies LTD ...

Reviews: