![Tadiran Telecom Swift Inverter 9U Service Manual Download Page 79](http://html1.mh-extra.com/html/tadiran-telecom/swift-inverter-9u/swift-inverter-9u_service-manual_3260285079.webp)
78
Electrical
Parts
(Main PCB)
1) Take all the connector of
PCB upper side out.(Including
Power cord)
2) Detach the outdoor unit
connection wire from the
terminal block.
3) If pulling the main PCB up,
it will be taken out.
air vent,
louver link
Remove axial sleeve of louver
link, bend the air vent outwards
and then remove the air vent
and louver link.
Pipeline
clamp
Remove the Pipeline clamp.
Mounting
plate
Remove the Mounting plate.