15
●
★
○
Internal coil
sensor error
Internal coil sensor, main internal control
panel.
16
○
★
●
Indoor fan error
Mechanical jam of fan, internal fan, main
internal control panel.
17
○
★
○
Refer to tooling
display for other
errors
Entire set of external controller.
18
●
●
★
Compressor cap
sensor error
System pressure, compressor cap sensor
(protection switch), main external control
panel.
19
●
○
★
Recirculated
sensor error
Recirculated sensor, four-way valve switch
error, main external control panel.
20
○
●
★
※
Compressor
overpower
protection
Power voltage, module panel, main
external control panel.
21
○
○
★
※
Over current
protection
Power voltage, system pressure, module
panel, main external control panel.
22
●
●
○
Exhaust sensor
error
System pressure, exhaust sensor, main
external control panel.
23
●
○
●
※
Cooling
overload
protection
Condenser, external fan, capillary, external
coil sensor, main external control panel.
24
○
●
●
※
Indoor high
temperature
heating protection
Evaporator, internal fan, thin unit
connection pipe, internal coil sensor, main
internal control panel.
25
●
○
○
※
Indoor
cooling freezing
protection
Evaporator, internal fan, capillary, internal
coil sensor, main internal control panel.
26
○
●
○
Compressor shell
temperature
protection
Same as "18 Compressor cap sensor error".
27
○
○
●
※
OVP or UPV
error
Power voltage, reactor, module panel, main
external control panel.
9-3 Troubleshooting for Normal Malfunction
The Foremost Inspecting Items
①
The input voltage must be 10% tolerance of the rated Voltage. If it is not
the case, the air-conditioner will probably not work normally.
②
Check the connecting cord between indoor unit and outdoor unit to see if it is
properly connected. The connecting must be done according to the wiring diagram,
Summary of Contents for Swift Inverter 9U
Page 1: ...Swift Inverter Split Type Air Conditioner...
Page 3: ...1 Part I Technical Information 1 Summary 1 1 Appearance Indoor Unit...
Page 4: ...2 Outdoor Unit 9K 12K 18K 24K 36K Note The outdoor grille can be replaced...
Page 28: ...27 Part II Installation and Maintenance 7 Main Tools for Installation and Maintenance...
Page 69: ...68 Remote Control Can Not Work Trouble shooting procedure...
Page 92: ...91 2 Swift Inverter 12U Exploded View...
Page 94: ...93 3 Swift Inverter 18U Exploded View...
Page 96: ...95 4 Swift Inverter 24U Exploded View...
Page 98: ...97 11 2 Outdoor Unit 1 Swift Inverter 9U Exploded View...
Page 100: ...99 2 Swift Inverter 12U Exploded View...
Page 102: ...101 3 Swift Inverter 18U Swift Inverter 24U Exploded View...