2.
Display error code of outdoor unit's indicator lights:
Display by the 3 LED indicator lights on the control panel of the outdoor unit:
○ for off; ● for on;
★
for flashing.
No
.
LE
D1
LE
D2
LE
D3
Error Name
Probable Trouble Location
1
○
○
○
Normal (outdoor
unit standby)
Normal, all three lights off for standby
status.
2
★
★
★
Normal
(compressor
running)
Normal, all three lights flash while
compressor running.
3
●
●
●
Forced service
(test mode)
Normal
4
★
★
●
Module
protection error
Power voltage, compressor cable, reactor,
module panel, main external control panel,
compressor.
5
★
★
○
PFC protection
error
Power voltage, reactor, module panel, main
external control panel.
6
★
●
★
Compressor
out-of-step error
Power voltage, compressor cable, module
panel, main external control panel,
compressor.
7
★
○
★
Exhaust air sensor
error
System pressure, exhaust air sensor, main
external control panel.
8
●
★
★
External coil
sensor error
External coil sensor, main external control
panel.
9
○
★
★
External room
temperature
sensor error
External room temperature sensor, main
external control panel.
10
★
●
●
Indoor and
outdoor unit
communication
error
Connection wire, main internal control
panel, main external control panel, EE
reverse connection, module panel.
11
★
●
○
Main external
control panel and
module panel
communication
error
Connection wire of module and main
control data, module panel, main external
control panel
12
★
○
●
Outdoor EE error Main external control panel
13
★
○
○
Outdoor DC fan
error
Mechanical jam of external fan, external
DC fan, main external control panel.
14
●
★
●
Internal room
temperature
sensor error
Internal room temperature sensor, main
internal control panel.
Summary of Contents for Swift Inverter 9U
Page 1: ...Swift Inverter Split Type Air Conditioner...
Page 3: ...1 Part I Technical Information 1 Summary 1 1 Appearance Indoor Unit...
Page 4: ...2 Outdoor Unit 9K 12K 18K 24K 36K Note The outdoor grille can be replaced...
Page 28: ...27 Part II Installation and Maintenance 7 Main Tools for Installation and Maintenance...
Page 69: ...68 Remote Control Can Not Work Trouble shooting procedure...
Page 92: ...91 2 Swift Inverter 12U Exploded View...
Page 94: ...93 3 Swift Inverter 18U Exploded View...
Page 96: ...95 4 Swift Inverter 24U Exploded View...
Page 98: ...97 11 2 Outdoor Unit 1 Swift Inverter 9U Exploded View...
Page 100: ...99 2 Swift Inverter 12U Exploded View...
Page 102: ...101 3 Swift Inverter 18U Swift Inverter 24U Exploded View...